9.2) Adjusting the device with remote programming via selector BATL7

For the remote programming of DIP S1 and of potentiometers from TM1 to TM5 to become operative,

The programming of all other parameters does not depend on DIP 12 of S1.
Comply with the following instructions to access the programming mode:

DIP12 of S1 must be

set to the ON position.

A) Move the selector’s locking key to the functions locked position

B) Press the selector’s SET

button and keep it depressed

C) Move the locking key back to the functions free position

.

D) Release the SET button

.

E) The yellow leds of the inputs will come on from left to right in sequence, to indicate that the data are being loaded (UPLOAD).

F) Once the UPLOAD phase has terminated, the red

led

and the yellow led

will come on.

G) The battery led shows that work is being carried out on DIP-SWITCH S1 while the yellow led indicates:

G1) that DIP1 of S1 is in the ON position issues an
G2) that DIP1 of S1 is in the OFF position if the led

.

H) Press the door free button

to change the status of the DIP-SWITCH (ON - OFF) .

I) Press button F1 to move to DIP2 of S1

.

L) Repeat the last operation to move to the other DIP-SWITCHES of S1.

M) Refer to sections 6 and 7 for the meaning of the DIP-SWITCHES.

N) To operate on DIP-SWITCH S2, press the SET

button. The LINE led

will come on.

O) Repeat the operations as given for MINIDIP S1 to select and change the status of the individual DIP-SWITCHES.

P) Press the SET button

to move to POTENTIOMETER TM1. The 2-WAY traffic led will come on

.

Q) When the potentiometers are being used, the input leds form a scale to indicate the set value.

R) To change the value of the selected potentiometer, press:

R1) the DOOR FREE button

to

.

R2) the F1 button

to

.

S) Press the SET button

to move to POTENTIOMETER TM2.

T) Repeat this last operation to move to the other potentiometers.

U) Refer to section 8 for the meaning of the potentiometers.

V) Comply with the following instructions to quit the programming phase and memorize the changed values:

V1) Move the selector’s locking key to the functions locked position
V2) Press the selector’s SET button and keep it depressed

del selettore.

V3) Move the locking key back to the functions free position

.

V4) Release the SET button

.

V5) The leds of the inputs will come on

in sequence to indicate

.

V6) The control unit will issue 2 bips once the

phase has terminated

V7) The selector will set back to the normal operating mode.

Z) Comply with the following instructions to quit the programming phase and

the changed values

Z1) Move the selector’s locking key to the functions locked position

.

Z2) Move the locking key back to the functions free position

.

Z3) The selector returns on normal operation and the control unit issues one single bip.

.

BATTERY

flashes

decrease the value

increase the value

from right to left

DOWNLOAD

DOWNLOAD

without memorizing

unbroken light.

F1

3

SET

SET

SET

SET

SET

SET

SET

Summary of Contents for BATL1

Page 1: ...GB Installation Manual SWING DOOR OPERATOR for one or two wings BATL1 Power opened spring closed BATL3 Power opened power closed ERREKA ERREKA BATL GB 10 06 CD0321 Rel 5 1...

Page 2: ......

Page 3: ...OF DIP SWITCH S1 22 7 DIP SWITCH S2 only via digital selector BATL7 23 8 POTENTIOMETER ADJUSTMENTS 24 9 DIGITAL SELECTOR BATL7 25 9 1 THE REMOTE CONTROL 26 9 2 ADJUSTING THE DEVICE WITH REMOTE PROGRAM...

Page 4: ...MECHANICAL SECTION BATL1 Power opened spring closed BATL3 Power opened power closed ERREKA 550 110 120...

Page 5: ...housing 7 Projecting pin 8 Spring locking screw 1 0 ACTUATOR COMPONENTS 1 Regulating dip switches and potentiometers 2 Powering board and connections 3 Spring 4 Spring preload reference 2 0 ARMS ARTI...

Page 6: ...for damage deriving from unauthorized modifications to the system Only use genuine spare parts if replacements or repairs are required The manufacturer cannot be held liable for the way the doors or g...

Page 7: ...the pin Bear in mind which type of arm either sliding or articulated and fixing method on the wall or wing will be used The actuator has two closing plugs for the pin outlets of which one is broken t...

Page 8: ...23 123 106 546 261 6 220 50 37 X 18 5 12 ARTICULATE PUSH ARM 7 0 TECHNICAL DRAWINGS 0 250 mm Fixing drawings available on request NOT Utilizable Length and weight Utilizable Length and weight Utilizab...

Page 9: ...15 123 123 106 546 23 261 20 5 0 200 261 18 5 12 X SLIDE PULL ARM 9 mm 1 1 NOT Utilizable Length and weight Utilizable Length and weight Utilizable Length and weight with different fixing sizes Fixing...

Page 10: ...ing the closing phase can be selected in the following way Connect the arm to the output shaft with the wing fully open so as to load the spring to the minimum Connect the arm to the output shaft with...

Page 11: ...e the standard preload and lock the spring Before you remove the arm you must restore the spring load to its standard value whereby the red mark on the belt matches the red mark on the pulley see figu...

Page 12: ...connect the arm from the conical connection by unscrew the two head screws Set the extension shaft in the conical connection like in figure Remember to keep the main screw inside conical connection Fi...

Page 13: ...ing and sliding components Lubricate closing spring if present Check wiring connections Check that arm connection screw are well tightened Check that door leaf are stable and the movement is steady wi...

Page 14: ...notes...

Page 15: ...ELECTRONIC SECTION BATL1 Power opened spring closed BATL3 Power opened power closed ERREKA ERREKA...

Page 16: ...The line is protected by the 5A fuse F1 TERMINAL BOARD M2 Terminals 1 3 4 connection of the FUNCTION SELECTOR switch installed on the side of the device central contact on common terminal 3 N C input...

Page 17: ...same signal match between selector and control unit Maximum cable length 20 meters Terminal 12 0 powering negative Terminal 13 DATA ITEM Terminal 14 12 Vdc powering positive Terminal 15 G ground Termi...

Page 18: ...see sect 13 Use the MASTER SLAVE wiring for BATL3 mod WR3MS Fig 2 BATL7 JUMPER J12 selects the door re closing speed in the absence of Only for the mains voltage BATL1 with Jumper in the 0 status low...

Page 19: ...Switch off the mains power supply 230V for about 5 seconds i Turn on the mains power again and wait for an acoustic signal BEEP j Set dip switch 6 of Minidip S1 to the OFF position k Switch off the ma...

Page 20: ...and the indications given by the warning light of selector BATL7 The effective intensity of this thrusting movement can be checked by obstructing the movement in order to stop the door and reverse its...

Page 21: ...keep the door completely open DOOR FREE to move the door in the manual mode without it being controlled by the motor TRAFFIC IN BOTH DIRECTIONS to open the door by means of all the command inputs EXIT...

Page 22: ...the door can only be opened with the EMERGENCY input or with the SPYCO radio control DIP 10 ON automatically increases the pause time if the door cannot close on account of the high flow of persons D...

Page 23: ...NG WITH SELECTOR ON see sect 14 DIP 4 ON PEDESTRIAN OPENING ENABLED see sect 14 OFF PEDESTRIAN OPENING INHIBITED see sect 14 DIP5 DELAY ON STARTING FOR TWO WING SWING DOOR see sect 13 Adjustment requi...

Page 24: ...ause time max 20 min 0 Closing upkeep voltage Wind stop force intensity Push Go activating distance Intensity of final thrust in last closing section to make it easier to fit into electro lock Power o...

Page 25: ...the key green led on to inhibit the stepping function activated by dip switch DIP 1 of S2 The package with digital selector BATL7 also contains the LOGIC TAST electronic board which is the interface m...

Page 26: ...ource while keeping button P1 depressed D The leds of the inputs will now start to show that the memory cells are being cancelled Release button P1 E Once all the cells have been cancelled the selecto...

Page 27: ...ven for MINIDIP S1 to select and change the status of the individual DIP SWITCHES P Press the SET button to move to POTENTIOMETER TM1 The 2 WAY traffic led will come on Q When the potentiometers are b...

Page 28: ...are the door for being opened when pushed by hand the next time Use digital selector BATL7 and press key green led on to automatically release the electro lock at the end of each door closing phase in...

Page 29: ...e potentiometer depending on the distance between the photocells see figure alongside 2 If the leds on the phtocells are off their sensitivity is correct 3 If the leds are on slowly turn the potentiom...

Page 30: ...handle the general operation of the door and a second control unit configured as the SLAVE which receives orders and information from the MASTER If one of the door wings overlaps the other during the...

Page 31: ...control unit Digital selector BATL7 see section 9 must be connected to the MASTER control unit so that the required operating program can be selected Power the SLAVE control unit at 230V a c via termi...

Page 32: ...t be delayed on starting set potentiometer TM2 closing speed of the MASTER control unit to a lower level about half than potentiometer TM2 of the SLAVE control unit However the MASTER actuator will st...

Page 33: ...Y inputs open both MASTER and SLAVE wings Manual pushing with the push go function only opens the pedestrian wing DIP SWITCH S1 SLAVE MASTER DIP 1 PUSH GO DIP 2 WIND STOP DIP 3 CYCLIC FUNCTION repeate...

Page 34: ...NOT USED 4 NOT USED 5 END OF TRAVEL DISTANCE ON OPENING 6 PUSHING POWER AT END OF OPENING MANOEUVRE 7 PUSHING POWER AT END OF CLOSING MANOEUVRE BATL3 version only 8 NOT USED 9 PUSHING TIME AT END OF C...

Page 35: ...oint 1 adjustment option simularly to the previous adjustments the yellow leds form a scale that indicates the value entered Press the key to decrease or the key to increase this value BATL7 Press SET...

Page 36: ...ion and preventing the manoeuvre from being completed Increase the value to obtain a higher power This is the pushing power in the last section of the closing phase It is useful for preventing frictio...

Page 37: ...he programming mode by means of the BATL7 selector B set dip switch 11 of switch S2 to the on position following the procedure described in sect 9 2 C quit the programming mode and memorize the data T...

Page 38: ...notes...

Page 39: ......

Page 40: ...RREKA ERREKA Automatic Doors Matz Erreka S Coop www erreka com San Juan auzoa 93 20570 Bergara Guipuzkoa Spain Tel 34 902 362 086 Fax e mail automaticdoors matz erreka es 34 943 769 901 Automatic Door...

Reviews: