27
F1
9.2) Adjusting the device with remote programming via selector BATL7
For the remote programming of DIP S1 and of potentiometers from TM1 to TM5 to become operative,
The programming of all other parameters does not depend on DIP 12 of S1.
Comply with the following instructions to access the programming mode:
DIP12 of S1 must be
set to the ON position.
A) Move the selector’s locking key to the functions locked position
B) Press the selector’s SET
button and keep it depressed
C) Move the locking key back to the functions free position
.
D) Release the SET button
.
E) The yellow leds of the inputs will come on from left to right in sequence, to indicate that the data are being loaded (UPLOAD).
F) Once the UPLOAD phase has terminated, the red
led
and the yellow led
will come on.
G) The battery led shows that work is being carried out on DIP-SWITCH S1 while the yellow led indicates:
G1) that DIP1 of S1 is in the ON position issues an
G2) that DIP1 of S1 is in the OFF position if the led
.
H) Press the door free button
to change the status of the DIP-SWITCH (ON - OFF) .
I) Press button F1 to move to DIP2 of S1
.
L) Repeat the last operation to move to the other DIP-SWITCHES of S1.
M) Refer to sections 6 and 7 for the meaning of the DIP-SWITCHES.
N) To operate on DIP-SWITCH S2, press the SET
button. The LINE led
will come on.
O) Repeat the operations as given for MINIDIP S1 to select and change the status of the individual DIP-SWITCHES.
P) Press the SET button
to move to POTENTIOMETER TM1. The 2-WAY traffic led will come on
.
Q) When the potentiometers are being used, the input leds form a scale to indicate the set value.
R) To change the value of the selected potentiometer, press:
R1) the DOOR FREE button
to
.
R2) the F1 button
to
.
S) Press the SET button
to move to POTENTIOMETER TM2.
T) Repeat this last operation to move to the other potentiometers.
U) Refer to section 8 for the meaning of the potentiometers.
V) Comply with the following instructions to quit the programming phase and memorize the changed values:
V1) Move the selector’s locking key to the functions locked position
V2) Press the selector’s SET button and keep it depressed
del selettore.
V3) Move the locking key back to the functions free position
.
V4) Release the SET button
.
V5) The leds of the inputs will come on
in sequence to indicate
.
V6) The control unit will issue 2 bips once the
phase has terminated
V7) The selector will set back to the normal operating mode.
Z) Comply with the following instructions to quit the programming phase and
the changed values
Z1) Move the selector’s locking key to the functions locked position
.
Z2) Move the locking key back to the functions free position
.
Z3) The selector returns on normal operation and the control unit issues one single bip.
.
BATTERY
flashes
decrease the value
increase the value
from right to left
DOWNLOAD
DOWNLOAD
without memorizing
unbroken light.
F1
3
SET
SET
SET
SET
SET
SET
SET