EMERGENCY RELEASE
In case of lack of electrical power, or loss of power, bypassing
the motor can unblock the gate:
1.
Open the closing cover
J
located on the front side of the
motor
2.
Insert key
K
in the lock, turn it clockwise and completely open
the plastic access flap
3.
Insert key
L
in the hole and rotate clockwise until end-stop
In order to restore the automation proceed as follows:
1.
Turn the key
L
in counter-clockwise sense until end-stop and
remove it
2.
Close the access flap and turn the key
K
in counter-clockwise
sense
3.
Cover the lock with the access flap
J
OPERATION END-STOP
For the end-stop operation, proceed as follows:
• Bring the shutter in position of maximum opening, then position the mechanical stop
A
, and shot effect, against the crosshead nut.
• Block the mechanical stop by fastening the bolt with a 13mm key.
• Bring the shutter in position of maximum closing, then position the mechanical stop
B
(accessory code AAX01), and shot effect, against
the crosshead nut.
• Block the mechanical stop by fastening the bolt with a 13mm key.