background image

Back light compensation (ICU and SATURN only)

In order to enable/disable Back light compensation, press:

Back light compensation
ON/OFF

Programming the Telemetry Receiver

The programming features are not available on the telemetry receivers Series BDR-51X.

Save preposition

To save preposition number 3, move the camera to the desired view, and press:

3

ð

ð

ESC

ð

ð

Save preposition number 3

Note: Valid range BDR-55X and ICU: 1-30,
BDR-575: 1-126, SATURN: 1-127.

Display preposition sequence stack (available on the BDR-55X only)

To display the sequence stack stored in the telemetry receiver currently being controlled:

ESC

ð

AUX

Display preposition sequence stack

Insert a preposition in the sequence stack

To insert preposition number 1 in the sequence stack stored in the telemetry receiver:

1

ð

ð

SHIFT

 +

INS

Insert preposition number 1 in the stack

Delete a preposition from the sequence stack

To delete preposition number 1 from the sequence stack stored in the telemetry receiver:

1

ð

ð

SHIFT

 +

DEL

Delete prepos. number 1 from the stack

Clear the preposition sequence stack

Clear the preposition sequence stack stored in the telemetry receiver currently being
controlled:

ESC

ð

ð

AUX

Clear the preposition sequence stack

1504M E-Mux & PTZ control

Page 10

2821-00062

Summary of Contents for 1504M

Page 1: ...7 27 07 E MAIL sally ernitec uk co uk FRENCH OFFICE ERNITEC FRANCE PARC PEREIRE 95 RUE PEREIRE BAT D 78100 SAINT GERMAINE EN LAYE FRANCE TELEPHONE 1 39 21 12 00 TELEFAX 1 39 21 12 95 E MAIL ernitec fr magic fr GERMAN OFFICE ERNITEC GmbH STORMARNRING 28 22145 STAPELFELD GERMANY TELEPHONE 040 67 56 25 0 TELEFAX 040 67 56 25 25 E MAIL ernitec aol com JAPAN OFFICE ERNITEC JAPAN LTD 8 16 GAKUEN HIGASHI...

Page 2: ...fied and approved with respect to EN 50081 1 and EN 50130 4 EMC and EN 60950 LVD Introduction The keyboard 1504M can be used for operating one E Mux Multiplexer as well as for direct operation of up to 32 telemetry receivers Series BDR 510 Series BDR 550 BDR 575 ICU and or SATURN Dome camera Keyboard connections The keyboard connections are shown on figure 1 Description 1 10 Power supply connector...

Page 3: ...n configuration and do not require additional line termination The ICU SATURN and the BDR 575 are bus connected and consequently the line must be terminated on the ICU with an external resistor on the BDR 575 by enabling the RS 485 LK1 jumper on the interface board and on the SATURN by setting a link across J9 For more details please refer to the documentation for the specific Telemetry Receiver D...

Page 4: ...e key F6 to select RS485 for PTZ control RS232 is automatically selected for E Mux control Set baud rate Press the F7 key to toggle between the valid baud rates for E Mux control The baud rate chosen must match the one set up for RS232 in the E Mux Baud rate 2400 is automatically selected for RS485 PTZ control Set the function of the AUX keys Press the F9 key to get to the AUX menu Press the F6 ke...

Page 5: ...1504M E Mux PTZ control 2821 00062 Page 5 ...

Page 6: ... only Enter Password XXXX F4 OpMode F6 Comm F7 Baud F9 XXXXXX XXXX XXXX More F4 Kbd No F6 AUX F7 Change F9 XX XX XXXX Password More Enter Password XXXX Reenter Password XXXX F4 ArcNet F6 Error F7 S W F9 Stat Log Ver More F4 Beep F6 Reset F7 Test F9 XXXX Settings Joystick More Set beeper tone Reset keyboard settings to default marked with an Test and re calibrate joystick Latch No Latch HIGH LOW OF...

Page 7: ...s should be operated simultaneously press Broadcast commands Warning When e g activating the pan functions all cameras will pan The broadcast function should therefore be used with care Zoom Change the focal length Joystick Joystick Zoom wide Zoom narrow Focus If the picture on the selected monitor is not in focus press Focus near Focus far Iris If the picture on the monitor is too dark or light p...

Page 8: ...d Pan tilt BDR 575 ICU or SATURN pushing the joystick towards its extremes will increase speed Activating an AUX relay To activate AUX relay 2 press 2 ð ð AUX Activate AUX 2 relay Note If the Keyboard is set for No Latch operation the relay is automatically de activated when the AUX key is released If set for Latch operation the relay will remain activated when the key is released De activating an...

Page 9: ...of pre positions press Start sequence The sequence of pre positions is automatically aborted when another function is operated Remove insert text Series BDR 550 only Remove insert the text generated by the currently controlled telemetry receiver Remove or Insert text from telemetry receiver Auto focus ICU and SATURN only In order to switch to auto focus press AUTO ð ð or AUTO ð ð Enable auto focus...

Page 10: ...y the sequence stack stored in the telemetry receiver currently being controlled ESC ð AUX Display preposition sequence stack Insert a preposition in the sequence stack To insert preposition number 1 in the sequence stack stored in the telemetry receiver 1 ð ð SHIFT INS Insert preposition number 1 in the stack Delete a preposition from the sequence stack To delete preposition number 1 from the seq...

Page 11: ... sec time out Note that the time out entry automatically is multiplied with 10 Max time out entry is 255 corresponding to 2550 seconds Set Auto panning limits available on the ICU SATURN BDR 575 only To set the two limit positions for auto panning for the camera being controlled 1 ð ð SHIFT AUTO and 2 ð ð SHIFT AUTO Set auto panning limit 1 left Set auto panning limit 2 right 1504M E Mux PTZ contr...

Page 12: ...set up the E Mux for 1504M control the following should be programmed Select E Mux control Mode To enter E Mux control mode press E MUX E Mux Control Mode Once in E Mux control mode it is not possible to control connected PTZ cameras To leave E Mux control mode and enter PTZ mode press the E MUX key again Toggle between display modes To toggle between the display modes pre programmed in the E Mux ...

Page 13: ...reen configuration PIP To enter PIP mode press SHIFT PIP mode To select a camera for the large window 3 ð ð Selects camera 3 for the large window To select a camera for the small PIP window 2 ð ð Selects camera 2 for the small PIP window Reposition small PIP window The Joystick can be used to reposition the small PIP window in one of the four corners or Reposition the small PIP window 1504M E Mux ...

Page 14: ...reen configuration To select vertical 2 Screen configuration press SHIFT Vertical 2 Screen To select a camera for the left window 3 ð ð Select camera 3 for left window To select a camera for the right window 2 ð ð Select camera 2 for right window Sequence In PIP mode or horizontal vertical 2 Screen a camera sequence can be started in the PIP window PIP mode or the bottom right window horizontal ve...

Page 15: ...nter programming mode of the E Mux PROG Enter programming mode The programming key is also used as the Enter key in the menus While in programming mode use the Joystick to navigate the menus Play To activate play view on the Main monitor PLAY Play view While in play mode select the required camera to view or select the desired multi screen view Record To activate record mode of the Multiplexer REC...

Page 16: ...om the VCR while in Play mode Direct multi screen configuration selection The following multi screen configuration modes can be selected directly SHIFT Full screen view on Main monitor SHIFT Quad split screen SHIFT 9 way split screen SHIFT 10 way split screen SHIFT 13 way split screen SHIFT 16 way split screen 1504M E Mux PTZ control Page 16 2821 00062 ...

Reviews: