background image

MAINTENANCE 

 

Page 12 

ROUTINE CHECKS 

 
Regularly the user should perform a basic check to verify if the 
water  filter  is  functioning  correctly,  on  the  basis  of  the 
following control points: 
1.

 

Check settings of electronic control panel. 

2.

 

Check water composition before/after water filter. 

3.

 

Check  drain  line  from  control  valve;  there  shouldn’t  be 
any water flow (unless water filter is in regeneration).  

4.

 

Check water filter and surrounding area; there shouldn’t 
be any water leakages. 

 

BYPASSING THE WATER FILTER 

 
Occasionally it may be necessary to put the unit hydraulically 
in bypass, i.e. to isolate it from the water distribution system; 
f.e.: 

 

replenishment of filter media; 

 

in case of an urgent technical problem; 

 

when  it  is  not  necessary to  supply treated  water  to  the 
house/application. 

 
WITH FACTORY BYPASS (optional)  
 

  

Picture 6.a

 

SERVICE POSITION 

 = inlet valve to water filter is OPEN 

 = outlet valve from water filter is OPEN 

 

  

Picture 6.b

 

BYPASS POSITION 

 = inlet valve to water filter is CLOSED 

 = outlet valve from water filter is CLOSED 

 

  

Picture 6.c

 

MAINTENANCE POSITION 

 = inlet valve to water filter is OPEN 

 = outlet valve from water filter is CLOSED 

 
WITH 3-VALVE BYPASS SYSTEM (not included)
 
 

  

Picture 7.a

 

SERVICE POSITION 

 = bypass valve is CLOSED 

 = inlet valve to water filter is OPEN 

 = outlet valve from water filter is OPEN 

 

  

Picture 7.b

 

BYPASS POSITION 

 = bypass valve is OPEN 

 = inlet valve to water filter is CLOSED 

 = outlet valve from water filter is CLOSED 

 

  

Picture 7.c

 

MAINTENANCE POSITION 

 = bypass valve is OPEN 

 = inlet valve to water filter is OPEN 

 = outlet valve from water filter is CLOSED 

 
 
 

FILTER MEDIA 

 
The  filter  media  inside  this  water  filter  consists  of  'self-
sacrificing' minerals, that dissolve in the acidic water to raise 
its  pH  to  neutral  level.  In  order  to  maintain  the  optimum 
performance of the water filter, the filter media needs to be 
replenished regularly. Ideally the level of filter media inside 
the pressure tank is kept between 1/2 and 2/3 of the pressure 
tank height. The frequency of replenishment depends on the 
water  usage  and  pH  of  the  incoming  water,  but  is  typically 
once or twice per year. 
 

  

Picture 8

 

The user should make sure there is always a sufficient amount 
of  filter  media  in  the  pressure  tank.  Therefore  he  should 
periodically  check  the  level  of  filter  media  and  refill  it  if 
necessary. The  easiest  way  to  do this is  by  holding  a bright 
light against the semi-transparent pressure tank, so that the 
top level of the filter media inside the pressure tank becomes 
visible.  
 
If the level of filter media has dropped below the minimum 
level, the user should refill it. 
1.

 

Put  the  bypass  system  of  the  water  filter  in  'bypass' 
position. 

2.

 

Manually initiate a regeneration, by pressing the scroll   
button repeatedly until the display shows:  

 
 
 

3.

 

Leave  the  water  filter  in  this  position;  the  countdown 
timer will countdown to 0 sec and start a regeneration. 

4.

 

Wait until the drive motor has driven the control valve in 
backwash position; the display will show: 

 
 
 
5.

 

Wait for 10-15 sec for the pressure inside the water filter 
to be relieved. 

6.

 

Unscrew  the  cap  from  the  media  fill  opening  on  the 
pressure tank. 

7.

 

Via  the  media  fill  opening,  pour  filter  media  in  the 
pressure tank as needed to reach the desired height. 

8.

 

Clean the threaded section of the media fill opening and 
screw the cap back on.  

9.

 

Manually initiate a regeneration, by pressing the scroll   
button repeatedly until the display shows:  

 
 
 

10.

 

Put the bypass system of the water filter back in 'service' 
position. 

 

 

 

Regen in 10 sec 

Rgn: 10 Cyc1:  8

 

Regen in 10 sec 

Summary of Contents for pHneutralizer Series

Page 1: ... 2014 erie water treatment TM EN pHneutralizer Rev2014 06 Technical Manual WATER FILTER pH correction ...

Page 2: ...age 5 Installation Page 6 Start up Page 7 Electronic control panel Page 8 Maintenance Page 12 Hydraulic flow diagrams Page 14 Troubleshooting Page 15 Electrical wiring diagram Page 16 Default parameter settings Page 17 Exploded view System Page 18 Exploded view Timer head Page 20 Exploded view Valve body Page 22 Technical data Page 24 ...

Page 3: ...e local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water filter make sure to check it for any externally visible damage do not install or use when damaged Use a hand truck to transport the water filter To prevent accident or injury do not hoist the water filter over your shoulder Do not lay the water filter on its side K...

Page 4: ...affected negatively if installed on a well verify that the well pump is powerful enough to provide sufficient flow rate for the regeneration cycle check water pressure regularly install a pressure reducer ahead of the water filter if necessary OPERATING TEMPERATURE min 4 max 38 C do not install the water filter in an environment where high ambient temperatures e g unvented boiler house or freezing...

Page 5: ... the tube 3 Place a funnel on the pressure tank opening and fill the pressure tank with the filter media make sure the riser assembly remains centered in the pressure tank 4 Rinse the pressure tank opening to remove any filter media from the threaded section 5 Unplug the top of the riser tube CONTROL VALVE 6 Make sure the O ring in the riser insert and the tank O ring around the threaded section o...

Page 6: ... water outlet of water filter treated water 1 Install the 3 valve bypass system 2 Screw the connection kit with nuts onto the in out ports on the control valve make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the 3 valve bypass system to the adaptors on the in and out port of the control valve 4 Connect the mains water supply to the inlet of the 3 valve bypass system...

Page 7: ...2 3 minutes open a cold treated water faucet nearby the water filter and let the water run until all air is purged from the installation and the filter media is properly rinsed it is normal for the rinse water to show some discoloration let the water run until the rinse water is clear close the tap 7 Check the water filter and all hydraulic connections for leaks Calcium magnesium will be added to ...

Page 8: ...lure the display will show the message If powering off on the water filter doesn t solve this problem professional service is required SERVICE MODE In service mode the display shows the time of day and the number of days remaining until the next regeneration REGENERATION MODE In regeneration mode the display shows the remaining regeneration time and the remaining cycle time The control valve can b...

Page 9: ... scroll button again the display will show Press the up or down button to set the number of days between regenerations The regeneration cycle is necessary to prevent caking of the filter media during the service cycle which may result in an increase of pressure drop over the water filter Typically a regeneration every 7 days should be sufficient In case of high flow rates excessive water usage or ...

Page 10: ...ation Before entering the programming mode make sure that the control valve is in the service mode 1 Press the scroll button and hold it for 5 sec until the display shows 2 Within 10 sec press the up button the display will show Press the up or down button to set the length of the regeneration cycle Press the scroll button again to advance to the next regeneration cycle Cycle 1 Backwash Cycle 2 Pu...

Page 11: ...Page 11 ...

Page 12: ... minerals that dissolve in the acidic water to raise its pH to neutral level In order to maintain the optimum performance of the water filter the filter media needs to be replenished regularly Ideally the level of filter media inside the pressure tank is kept between 1 2 and 2 3 of the pressure tank height The frequency of replenishment depends on the water usage and pH of the incoming water but i...

Page 13: ...ect or contaminate your water supply However as in any device plumbed in in your water distribution system a proliferation of bacteria is possible especially in case of stagnant water Therefore this water filter will automatically rinse the filter media periodically If the power supply to the water filter is disconnected for a longer period of time we recommend when the power supply is re establis...

Page 14: ...HYDRAULIC FLOW DIAGRAMS Page 14 SERVICE BACKWASH PURGE ...

Page 15: ...ace drive motor micro switches Defective PCB Replace PCB Drain line from control valve flows continuously Water filter in regeneration Wait until regeneration finishes or manually advance regeneration to end Faulty electrical supply Verify electrical service fuse transformer Defective drive motor Replace drive motor Defective micro switch Replace micro switches Defective PCB Replace PCB Valve body...

Page 16: ...ELECTRICAL WIRING DIAGRAM Page 16 position switches power lead drive motor auxilliary contact 24V max 500mA key pad ...

Page 17: ...ge 17 Model pHneutralizer pHneutralizerXL Filter media quantity Cuft Ltr 1 28 1 5 42 1 28 1 5 42 Interval days 7 7 7 7 Cycle 1 BACKWASH min 8 8 8 8 Cycle 2 SLOW RINSE min 0 0 0 0 Cycle 3 PURGE min 2 2 2 2 Regen 0 00 0 00 0 00 0 00 ...

Page 18: ...EXPLODED VIEW SYSTEM Page 18 ...

Page 19: ... 30 mix multiple of 0 5 Cuft 3 A1000 Gravel 4 3 kg to be ordered per kg 4 38534 Riser tube assembly to be cut to length 5 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 6 287 166 LS Top distributor 7 2400TF JN AUX Control valve 8 568 303 1 Connection kit 1 BSP male 9 38522 Drain hose to be ordered per meter 10 38521 Clamp drain hose 2x 11 74163 Air gap with double hose barb Recommended Spare ...

Page 20: ...EXPLODED VIEW TIMER HEAD Page 20 ...

Page 21: ...or assy 2x 9 28 245 4 Cable clamp 10 71502 Strain relief power lead 11 72261 Drive motor 12 568 227 2 Worm 13 19 48 Retaining ring 14 70965 Switch cam 15 568 386 Bracket micro switches 16 568 310 Gear switch cam 17 15 184 7 Locking screw switch cam 18 15 173 12 Screw micro switches 2x 19 72451 Micro switch assy 20 71679 Cable set drive motor 21 15 102 Screw PCB 2x 22 72703 Printed Circuit Board 23...

Page 22: ...EXPLODED VIEW VALVE BODY Page 22 ...

Page 23: ... 16 568 270 4 Float valve 17 568 274 5 Injector green 18 186 118 O ring plug small 19 541 273 Plug small 20 541 254 Spring clip plug small 21 570 251 Gasket riser 22 568 334 Riser insert 23 185 214 1 O ring riser tube 24 185 337 1 O ring tank 25 541 232 Adapter ring 26 15 207 12 Screw adapter ring 2x 27 72772 Packing gland nut plastic 28 185 211 1 O ring packing gland nut 29 186 115 O ring worm dr...

Page 24: ...tralizerXL Filter media quantity Cuft Ltr 1 28 1 5 42 1 28 1 5 42 Recommended max service flow m3 hr 2 1 4 1 6 1 4 1 6 Nominal backwash flow flow to drain Ltr min 23 Rinse water usage per regeneration Ltr 227 2 continuous service flow rates higher up to x2 short period peak flow rates are possible Dimensions and weights Model pHneutralizer pHneutralizerXL Filter media quantity Cuft Ltr 1 28 1 5 42...

Page 25: ... 2012 Aquion Inc PP Neutralizer Rev2014 03 r 1 a r 1 b 2 a 2 b 3 a 3 b ...

Page 26: ... 2012 Aquion Inc PP Neutralizer Rev2014 03 r 4 a r 4 b 5 r 6 a r 6 b ...

Page 27: ... 2012 Aquion Inc PP Neutralizer Rev2014 03 r 6 c 7 a 7 b r 7 c ...

Page 28: ... 2012 Aquion Inc PP Neutralizer Rev2014 03 r 8 ...

Page 29: ...AQUION INC Lammerdries Oost 30c B 2250 Olen Belgium 32 0 14 28 51 71 32 0 14 28 51 70 RPR RPM Turnhout BWT TVA VAT BE 0882 738 206 infobelgium eriewatertreatment com www eriewatertreatment com ...

Reviews: