MINI-LINK E and E Micro
Test Port In
Test Port Out
Traffic In
Traffic Out
Test Port In
Test Port Out
Traffic In
Traffic Out
Analyser
Monit or
BIT
Generator
BER
Detector
Route
3576
Figure 76
Test Port facilities: Monitor and Route
6.1.7
Other Control Functions
Other control functions are:
P-mark
P-mark is a valuable facility during fault location. With P-mark activated, all
alarm signals are generated and can be read in the normal way, but alarm
notification messages are inhibited.
TX On/Off
Transmitter can be set on or off.
Switch Mode (for 1+1 configurations only, applicable for MINI-LINK E)
Can be set to auto or manual. In automatic mode (set by default) switching is
controlled by the state of different alarms. See Section 3.9.2.6 on page 58 for
details. In manual mode, the user selects transmitting (1+1 Hot standby only)
and receiving radio, irrespective of alarm status.
Restore
For resetting of the control functions in the terminal to default values.
Reset
Used to reset the processor in a selected unit within the terminal.
107
AE/LZT 110 2012 R8C 2002-03-04
Summary of Contents for MINI-LINK E
Page 1: ...MINI LINK E and E Micro Technical Description MINI LINK...
Page 2: ......
Page 3: ...MINI LINK E and E Micro Technical Description E...
Page 28: ...MINI LINK E and E Micro 22 AE LZT 110 2012 R8C 2002 03 04...
Page 84: ...MINI LINK E and E Micro 78 AE LZT 110 2012 R8C 2002 03 04...
Page 98: ...MINI LINK E and E Micro 92 AE LZT 110 2012 R8C 2002 03 04...
Page 180: ...MINI LINK E and E Micro 174 AE LZT 110 2012 R8C 2002 03 04...
Page 184: ...Glossary 178 AE LZT 110 2012 R8C 2002 03 04...
Page 188: ...Index 182 AE LZT 110 2012 R8C 2002 03 04...
Page 189: ......