LBI-38962
39
Problem
Corrective Actions
Time interval between consecutive
calls is excessive.
1. Verify that the radio is in range and isn't being interfered
with.
2. Verify that the SYSTEM.TXT Outbound_Msg_Delay value
isn't too large.
TSI Boards run out of memory.
1. Reduce the SYSTEM.TXT Max_Msgs or the Msg_Timeout
values.
Radio originated message doesn't
reach the host
1. Radio LID is defined as a network layer RDT in
SYSTEM.TXT, but EDACS Network Driver is not installed at
RDT.
2. EDACS Network Driver is installed at RDT, but radio LID
is not defined as a network layer RDT in SYSTEM.TXT.
3. RDI set up to use BREN, but TSI_ANTI_BIASING
command in SYSTEM.TXT is not set to TRUE.
Extra data bytes prepended to data
received at RDT.
1. Radio LID or GID is defined as a network layer RDT in
SYSTEM.TXT, but EDACS Network Driver is not installed at
RDT.
Data received at RDT or host is
garbled.
1. RDI set up to use BREN, but TSI_ANTI_BIASING
command in SYSTEM.TXT is not set to TRUE.
2. TSI_ANTI_BIASING command in SYSTEM.TXT is set to
TRUE, but RDI is not set up to use BREN.