5 (5)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr -
No.
SES/KTR Mats Andersson
KTR97:2486
Dokansv/Godk -
Doc respons/Approved
Kontr -
Checked
Datum -
Date
Rev
File
KTR M. Andersson
1997-12-07
A
97-2486-FAULT TRACING F800.doc
3.8
FAN TEST
The fan is controlled by the transceiver unit and operating only when the
station is keyed.
If the fan does not start when the station is keyed, check that the transceiver
unit supplies 12V on P7:1 on the interconnection board. If 12V is present,
replace the fan. If the transceiver does not provide 12V on P7:1 it is faulty.