19
3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2 Quick Reference Guide
A module is taken Out-of-Service by an operator shutdown-
command or by activation of the shutdown button.
1.7.3
Hot insertion and removal
The AXX 9100 CONNECT service modules supports hot insertion
and removal. Each module contain a switch that is activated when
the module shall be removed. A special tool, the Card Extraction
Tool must be used to activate the switch.
Figure 8 Switch to be activated when the module shall be removed
When the module shall be replaced the switch must be activated
and the you must wait for the LED to extinguish before the module
is removed.
Warning!
When activating the switch, ensure that it is not pressed to fare
in.
It is also possible to deactivate the module from the craft terminal
AXX 9820 CRAFT.
When the switch is activated, the module is disabled in SW, and the
MOD FAIL LED is switched off (for modules carrying IP, the LED
blinks during SW cleanup, and extinguishes afterwards).The
module can now be removed. Please see Figure 9
switch