© 2001 – Ericsson Amplifier Technologies Inc.
25
5. MAINTENANCE
5.1 Introduction
This section provides information for periodic maintenance of the MCPA, as well as
tests which are recommended in order to evaluate performance of the amplifier. Refer
to paragraph 5.3 for troubleshooting procedures for the MCPA.
CAUTION
Do not attempt to repair the MCPA. The amplifier
contains no user-serviceable components, with the
exception of the fan assemblies. Further damage will
result from improper repairs.
NOTE
Do not break the seals on the equipment, as this will void
the warranty.
5.2 Periodic Maintenance
Periodic maintenance tasks and recommended intervals are listed in Table 4.
Table 4. Periodic Maintenance Tasks
CATEGORY
TASK
RECOMMENDED
INTERVAL
MAINTENANCE ACTION
Cleaning
Fans, Air
Inlets/Outlets
30 Days
Inspect and clean in accordance
with paragraph 5.2.1.
Inspection
Cables and
Connectors
12 Months
Inspect all cables for any signs of
damage or wear. Check and
verify that all connections are
secure.
Performance
Tests
12 Months
Perform tests as outlined in
paragraph 5.2.3.