background image

 

 

 

 

 

 

 

Operating Instruction 

Spindle lifting system SLA/SLG VD

 

 

 

Document no.: B-00081 

Edition 2019 02

 

Operating instruction EN 

Copyright by Ergoswiss AG

 

16/20 

 

7

 

Safety strip - Squeezing protection 

With lifting systems of Ergoswiss AG it is important to make sure that no objects or people are trapped dur-

ing the lifting movement. ->

Danger of squeezing

 

Attach the safety strip to an assumed squeeze zone. If the safety strip gets squeezed while the system 

moves, the motor will stop instantly and turn back for 14 motor turns. 

 

The safety strip VD cpl. (124.00156) consists of: 

 

 

7.1

 

Technical Data 

Functional properties of the contact tube 

Contact angle    

 

< 80 ° 

Switching pressure 

 

< 25 N bei 23 °C 

Switching travel   

 

< 2 mm bei 23 °C 

Bending radii minimal 

 

B

1

 120 mm / B

2

 150 mm  

 

 

 

 

B

3

 20 mm / B

4

 20 mm 

Max. tensile load   

 

20 N 

 

Electrical properties 

Terminal resistance  

 

2.2 kOhm 

Max. switching capacity   

250 mW 

Max. voltage 

 

 

DC 24 V 

Current min. / max. 

 

1 mA / 10 mA

 

 

 

 

 

 

 

 

 

Gluing the contact tube in the squeeze zone 

Connecting the safety strip 

1.

 

Clean and degrease the contact face 

2.

 

Pull off a liner of acrylic foam of 10 to 15 cm 

3.

 

Place it on the contact face and press on well 

4.

 

Repeat steps 2 and 3 until the contact tube is 

completely glued on 

5.

 

Maximum adhesion is reached after 24 h 

1.

 

Run the cable 124.00107 orderly to avoid en-

tanglement 

2.

 

Connect the adapter plug to the control box 

3.

 

The safety strip must be connected to the con-

trol box before the control box is connected to 

the mains. If the safety strip is connected after-

wards, it will not be recognised by the control 

box!

 

 

 

End piece with cable / RJ45 

124.00107 

Contact tube 

124.00101 

 

End piece with 

resistor 2.2k 

124.00118 

 

2500 mm 

variable (100 – 5'000 mm) 

10 mm 

Summary of Contents for 903.20033

Page 1: ...Control box VD SCT Manual control switch Up Down or Memory Errors and technical changes reserved Ergoswiss AG does not assume any liability for operating errors or using the products outside of the i...

Page 2: ...SLA SLG 4330 Number of linear units 1 2 3 4 4330 Spindle pitch in mm 3 mm 4330 Stroke length in cm 30 40 cm EU Power cable EU CH IT UK US 11 11 manual control switch up down 12 Memory 11 12 VD Lifting...

Page 3: ...tch VD Memory 10 3 2 3 Manual control switch VD Memory T6 11 4 Initial operation 12 5 Operation 13 5 1 Drive up down 13 5 2 Duty cycle monitoring 13 5 3 Saving a memory position Only with manual contr...

Page 4: ...is con tinuously shown on the display cm or inches Up to three different memory positions can be stored and approached individually 1 2 Intended purpose use The lifting system SLA SLG is used in appli...

Page 5: ...oment 200 Nm Max dyn Bending moment 80 Nm 1 4 3 Motor SX D30 24 V Nominal voltage 24 V Nominal torque 2 5 Nm Idle speed 352 min 1 Nominal power 64 W Nominal current 5 55 A no load current 0 33 A 1 4 4...

Page 6: ...ate threatening danger Non compliance with this information can result in death or serious personal injuries invalid ity WARNING Indicates a possible dangerous situation Non compliance with this infor...

Page 7: ...potentially explosive atmosphere The control box must be protected from moisture dripping water as well as spray water The control box is not suitable for continuous use The operation hold ratio must...

Page 8: ...r by instructions in the operating instructions and or by safety instructions on the system 3 1 Mounting the control box and connecting the cables Mounting of the control box underneath a table top AT...

Page 9: ...the control box Please follow the order M1 M4 2 Connect the manual control switch to the control box 3 Connect the power cable to the control box 4 Connect the power cable to the mains Clicking sound...

Page 10: ...nderneath the table top The control panel must overhang below the work surface 2 Fasten the manual control switch using the mounting screws Be careful not to drill through the table top 3 2 2 Manual c...

Page 11: ...pyright by Ergoswiss AG 11 20 3 2 3 Manual control switch VD Memory T6 1 Position the manual control switch at the desired loca tion underneath the table top The control panel must overhang below the...

Page 12: ...within the danger area and no one is reaching into the danger zone ATTENTION The lowest block position must always be reachable The lifting element is not allowed to hit a stop before it reached its...

Page 13: ...s to be observed before the system can be operated again 5 3 Saving a memory position Only with manual control switch type Memory With this function it is possible to memorise a certain position heigh...

Page 14: ...wer position will be limited Container Stop NOTE For a Container Stop position and Shelf Stop position these steps must be performed sepa rately To deactivate an existing Container Stop Shelf Stop pos...

Page 15: ...g Disconnect the plug carefully risk of damage 6 2 Commissioning the synchronized system 1 Connect the drives according to the manual 2 Connect the control boxes using the SYNC 2 cable VD 3 Connect th...

Page 16: ...B2 150 mm B3 20 mm B4 20 mm Max tensile load 20 N Electrical properties Terminal resistance 2 2 kOhm Max switching capacity 250 mW Max voltage DC 24 V Current min max 1 mA 10 mA Gluing the contact tub...

Page 17: ...ginal replacement parts may be used For all repair work the system must always be unloaded and voltage free ATTENTION In no case may the control box be opened There is the risk of an electrical shock...

Page 18: ...Hall sensor no signal A 113 A 71 Hall sensor wrong motor movement A 114 A 72 Motor missing no connection A 115 A 73 Motor missing no power A 201 A C9 Lock duty cycle monitoring The drives were operat...

Page 19: ...not connected Connect motor cable Motor defective Contact the customer service Control box defective Contact the customer service Manual control switch defective Replace the manual control switch Bad...