Operating instruction
Spindle lifting system SL/SK/SM 14xx Compact
Document no.: B-00061
Edition 2022 05
Operating instruction EN
Copyright by Ergoswiss AG
Page
24
of
26
9.5
Error codes on the display
Display
Cause
Trouble shooting
The control box compact is equipped
with an overheating protection.
This overheating protection will activate
due to too high temperatures
Wait until the control box has cooled down and the
message
«HOT»
is no longer displayed.
Then the control box is ready for operation again.
There is an internal error at the control
box.
Proceed according to the following error list.
blinking
000
Motor position lost
Perform a «Long Key Down».
00
Internal error channel 1
Disconnect the power cable from the mains and
contact the customer service.
01
Internal error channel 2
12
Defective channel 1
Insert the motor cable correctly.
13
Defective channel 2
24
Excess current motor M1
System overloaded
→
Remove load from the system
System jammed
→
remove clamped object
25
Excess current motor M2
48
Excess current motor group 1
49
Excess current motor group 2
60
Collision protection
62
Excess current at the control
36
Plug detection at motor socket M1
Plug in the motor cable correctly at the respective
socket.
Perform a Factory reset «S 0».
37
Plug detection at motor socket M2
61
Motor replaced
55
Synchronising of the motor group 1
impossible
Remove load from the system.
Perform a Factory reset «S 0».
Contact the customer service if the error remains
displayed.
56
Synchronising of the motor group 2
impossible
67
Too high voltage
Disconnect the power cable from the mains.
Contact the customer service.
70
Change of the drive configuration
Disconnect the power cable from the mains and
wait at least for 5 seconds.
Reconnect the power cable.
Perform a Factory reset «S 0».
81
Internal error
Disconnect the power cable from the mains and
wait at least for 5 seconds.
Reconnect the power cable.
Perform a Factory reset «S 0».
Contact the customer service if the error remains
displayed.
93
Connection error while synchronising
The error is displayed for 15 seconds,
then the control box changes to the re-
set mode with a flashing display of
«000»
.
Disconnect the power cable from the mains and
wait at least for 5 seconds.
Reconnect the power cable.
Perform a Factory reset «S 0».