3.2
Montage instructions Control box
Mounting of the control box underneath a table top:
ATTENTION
During mounting of the control box the power cable needs to be disconnected from the
mains!
1.
Place the control box to the desired location and mark the drill holes with a pen.
2.
Pre-drill two holes (Ø 3 mm /
0.12’’)
.
Be careful not to drill through the table top!
3.
Mount the control box with 2 screws.
(e.g.: Button head screw DIN 7981-C, Ø 4.8 mm
(0.19”)
, head-Ø 9.5 mm / 0.37’’).
NOTE
When tightening the screws do not exceed a maximum torque of 2 Nm
(1.5 lbf
⋅
ft)
!
NOTE
The motor cable has a length of 1’800 mm
(70.9’’)
. If needed, up to 4 motor extension cables
can be connected. They have a length of 1’200 mm
(47.2’’)
each.
124.00137: Extension cable Motor SCT/Compact 1.2m
(47.2’’)
NOTE
The cable of the hand switch has a length of 1’700 mm
(66.9’’)
. If needed it can be expanded
with up to 3 extension cables. They have a length of 1’000 mm
(39.4’’)
each.
124.00071: Extension cable Hand switch Compact 1m
(39.4’’)