Appendix
12/2012
1012945-00
Operating instructions – 53/56
7.3
Equivalence key range
Example for calculating the equivalence key range (1), see the lamp
configuration sticker:
If the equivalence key of the lamp with which the device has been equipped
during the type approval is
100–R–47/3.2,
the equivalence key range with which the device should be marked is calcu-
lated as follows:
Bottom value of the X section:
0.75 x 47 = 35.25
Bottom value of the Y section:
0.85 x 3.2 = 2.72
Top value of the Y section:
1.15 x 3.2 = 3.68
X is rounded up to the next whole value, Y will be rounded to the first decimal
place after the point. The equivalence key range for fluorescent lamps is then:
100–R–(35-47)/(2.7-3.7)
7.3.1
Description of the equivalence keys for
UV fluorescent lamps
The equivalence key for UV fluorescent lamps for tanning that is represented
in detail in the IEC 61228 and that is marked on the lamp in a readable and
permanent manner, is described in the following.
The equivalence key has the following structure:
Wattage – Reflector type key – UV key.
The following reflector type key should be used for the equivalence key:
O with lamps without reflector;
B with lamps that have a wide reflecting angle
> 230°;
N with lamps that have a narrow reflecting angle
< 200°;
R with lamps that have the usual reflecting angle
200°
230°.
Summary of Contents for ESSENCE 440 SMART POWER 200
Page 2: ......
Page 3: ...Original Gebrauchsanweisung 1012945 00 de 12 2012 ESSENCE 440 SMART POWER 200 VIBRA SHAPE ...
Page 53: ...Anhang 12 2012 1012945 00 Gebrauchsanweisung 51 58 2 Aufkleber Wartungshinweis 800701 ...
Page 54: ...Anhang 52 58 3 Aufkleber Anschluss 1009050 Der Aufkleber befindet sich hinter der Blende ...
Page 60: ...Index 58 58 ...
Page 110: ...Appendix 50 56 2 Maintenance instruction sticker 800701 ...
Page 117: ......
Page 118: ......
Page 119: ......