EG-IoT_UG_demonstrator_006_UK
.docx
Page 28 / 34
Descriptions and non-contractual illustrations in this document are given as an indication only. ERCOGENER SAS reserves the right to make any
modifications. This document is the property of ERCOGENER SAS. It may not be reproduced or disclosed to a third party without the written
consent of ERCOGENER SAS.
6.1.3.7
Frame sent via SMS
SMS
Unit
Nb car
min.
Nb car
max.
Value
min.
Value
max.
Example
GSM IMEI/
Custom ID
-
0
15
-
-
123456789012345
Op code
-
2
2
11
FE
11
11
Life frame
Date
ddmmyyyy
8
8
10012017
17
Alarm frame
Hour
hhmm
4
4
0000
2359
1221
FE
Service Init.
Counter 1
-
1
5
0
65535
47
Counter 2
-
1
5
0
65535
259
Alarm status
-
2
2
00
FF
00
b0
Status input 1
Reserved
-
1
1
0
0
0
b1
Status input 2
Reserved
-
1
1
0
0
0
b2
Alarm counter 1
V
BAT
mV
4
4
0
9999
3609
0
< Threshold
Temp.
°C
2
2
-40
+86
26
1
≥ Threshold
b3
Alarm counter 2
0
< Threshold
1
≥ Threshold
b4
Alarm low Temp.
0
< Threshold
1
≥ Threshold
b5
Alarm high Temp.
0
< Threshold
1
≥ Threshold
b6, b7
Reserved
Reserved
-
1
1
0
0
0
Status input 1
-
1
1
0
1
0
Status input 2
-
1
1
0
1
1
Number of character per
frame with separator
42
65
Example of frame:
ID ................................... :
1234564798012345
Opcode .......................... :
Life frame
11
Date ............................... :
10012017
Time ............................... :
1221
Value counter 1 .............. :
47
Value counter 2 .............. :
259
Alarms status ................. :
00
Reserved ....................... :
none
0
Reserved ....................... :
none
0
V
BAT
................................ :
3.609V
3609
Temp. ............................ :
26°C
26
Reserved ....................... :
none
0
Status input 1 ................. :
none
0
Status input 2 ................. :
none
0
SMS
1234564798012345,11,10012017,1221,47,259,00,0,0,3609,26,0,0,0