Erbauer ERN634ATL Handbook Download Page 13

1/2" AIR RATCHET WRENCH

1. Flush the tool with air-tool oil or gum 
    solvent.
2. Lubricate the tool.
3. a. Adjust the regulator on the tool to 
    maximum setting.
    b. Adjust the compressor regulator to tool 
    maximum of 90 PSI/6.3 BAR.
4. Tighten and seal hose fittings if leaks are 
    found. Use sealing tape.
5. a. Be sure the hose is the proper size. 
    Long hose or tools using large volumes 
    of air may require a hose with an I.D. of 
    1/2 in. or larger depending on the total
    length of the hoses.
    b. Do not use a multiple number of hoses 
    connected together with quick-connect 
    fittings. This causes additional pressure 
    drops and reduces the tool power. 
    Directly connect the hoses together.
6. Replace rotor blade.
7. Water in tank; drain tank. (See air 
    compressor manual). Oil tool and run 
    until no water is evident. Oil tool again 
    and run 1-2 seconds.

Tool runs 
slowly or will 
not operate

1. Grit or gum in tool.

2. No oil in tool.
3. Low air pressure.

4. Air hose leaks.

5. Pressure drops.

6. Worn rotor blade.
7. Moisture blowing 
    out of tool exhaust.                                                               

PROBLEM

TROUBLESHOOTING

                     CORRECTIVE ACTION

POSSIBLE CAUSE

CARE AND MAINTENANCE

An in-line oiler is recommended to be installed on air supply line as it increases tool 
life and keeps the tool in sustained operation. The in-line oiler should be regularly 
checked and filled with air-tool oil. Proper adjustment of the in-line oiler is performed 
by placing a sheet of paper next to the tool's exhaust ports and holding the throttle 
open approximately 30 seconds. The in-line oiler is properly set when a light stain of 
oil collects on the paper. Excessive amounts of oil should be avoided.

In the event that it becomes necessary to store the tool for an extended period of 
time, it should receive a generous amount of lubrication at that time. The tool should 
be run for approximately 30 seconds to ensure oil has been evenly distributed 
throughout the tool. The tool should be stored in a clean and dry environment.

Recommended lubricants: use air-tool oil or any other high-grade turbine oil 
containing moisture absorbent, rust inhibitors, metal wetting agents and an EP 
(extreme pressure) additive.

Clean the tool all over with a cotton rag after each use. Keep the tool in a dry and 
safe place out of reach of children.

Summary of Contents for ERN634ATL

Page 1: ...1 2 AIR RATCHET WRENCH ERN634ATL...

Page 2: ...er s guidelines Loss of use of the goods Congratulations on your purchase of a quality power tool from Erbauer UK Ltd This product should give you reliable service but for your peace of mind this powe...

Page 3: ...d or under the influence of alcohol drugs or medication 2 Do not overreach Keep proper footing and balance at all times 3 Always wear eye protectors which provides protection from flying particles fro...

Page 4: ...o a complete stop before putting it down after use 11 If necessary use clamps or proper devices to securely fix the workpiece when installing tightening or removing loosening threaded fasteners on the...

Page 5: ...creen filter for blockage weekly Clean if necessary 8 Usually a 3 8 inner diameter air hose is recommended for air supply and airflow to get the optimum performance of tool 9 A long air hose usually o...

Page 6: ...roperty SYMBOLS Revolution per minute Pound per square inch RPM PSI CFM Cubic feet per minute Caution Warning Read the instruction manual Wear hearing protection Wear eye protection xxWxx Manufacturin...

Page 7: ...RATCHET WRENCH PRODUCT DESCRIPTION DESCRIPTION QUANTITY PART F R Knob Exhaust Deflector 1 2 Air Ratchet Wrench Steel Ball Air Inlet Air Regulator Trigger Anvil 1 1 1 1 1 1 1 1 A B C D E F G H H A G C...

Page 8: ...sed in a preliminary assessment of exposure The declared vibration total value has been measured in accordance with a standard test method and may be used for comparing one tool with another The decla...

Page 9: ...vibration syndrome if its use is not adequately managed WARNING The vibration emission value during actual use of the power tool can differ from the declared value depending on the ways in which the...

Page 10: ...ee Figure 1 3 Place 2 3 drops of air tool oil not included into the male plug before each use See Figure 3 2 Mount the male plug by hand into the air inlet E See Figure 2 NOTE Use thread sealant tape...

Page 11: ...F position F Forward or Tighten Press the trigger G The tool anvil H runs clockwise See Figure 6 5 Connect air supply hose to the male plug See Figure 5 WARNING Only use impact sockets that have a RPM...

Page 12: ...til desired output is achieved The settings 1 2 3 4 are only for reference and do not denote a specific power output Setting 1 one line symbol is the least amount of power while Setting 4 four line sy...

Page 13: ...LEM TROUBLESHOOTING CORRECTIVE ACTION POSSIBLE CAUSE CARE AND MAINTENANCE An in line oiler is recommended to be installed on air supply line as it increases tool life and keeps the tool in sustained o...

Page 14: ...1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 Pin Front plate Bearing Washer Thread ring gear Idle gear G...

Page 15: ...natory and technical file holder Date 05 05 2015 Signature Name title Peter Harries Quality Manager Erbauer UK Ltd Trade House Mead Avenue BA22 8RT Complies with the following Directive s EC Machinery...

Page 16: ...1 2 AIR RATCHET WRENCH...

Reviews: