background image

Safety instructions

GENERAL POWER TOOL SAFETY WARNING

7

WARNING: Read all safety warnings, instructions, illustrations and 
specifications provided with this power tool. 

Failure to follow all 

instructions listed below may result in electric shock, fire and/or serious 

injury.

Save all warnings and instructions for future reference.

The term "power tool" in the warnings refers to your mains-operated 

(corded) power tool or battery-operated (cordless) power tool.

1) Work area safety

a) Keep work area clean and well lit. 

Cluttered or dark areas invite accidents.

b) Do not operate power tools in explosive atmospheres, such as in the 
presence of flammable liquids, gases or dust.

 Power tools create sparks which 

may ignite the dust or fumes.

c) Keep children and bystanders away while operating a power tool. 

Distrac-

tions can cause you to lose control.

2) Electrical safety

a) Power tool plugs must match the outlet. Never modify the plug in any way. 
Do not use any adapter plugs with earthed (grounded) power tools. 

Unmodi-

fied plugs and matching outlets will reduce risk of electric shock.

b) Avoid body contact with earthed or grounded surfaces, such as pipes, 
radiators, ranges and refrigerators. 

There is an increased risk of electric shock if 

your body is earthed or grounded.

c) Do not expose power tools to rain or wet conditions. 

Water entering a power 

tool will increase the risk of electric shock.

d) Do not abuse the cord. Never use the cord for carrying, pulling or unplug-
ging the power tool. Keep cord away from heat, oil, sharp edges or moving 
parts. 

Damaged or entangled cords increase the risk of electric shock.

e) When operating a power tool outdoors, use an extension cord suitable for
outdoor use. 

Use of a cord suitable for outdoor use reduces the risk of electric 

shock.

f) If operating a power tool in a damp location is unavoidable, use a residual 
current device (RCD) protected supply. 

Use of an RCD reduces the risk of 

electric shock.

NOTE The term “residual current device (RCD)” can be replaced by the term 

“ground fault circuit interrupter (GFCI)” or “earth leakage circuit breaker (ELCB)”.

Summary of Contents for 3663602796794

Page 1: ...EHSS350 EAN 3663602796794 ORIGINAL INSTRUCTIONS MNL_EHSS350_V03_BX220IM 10 8 2020...

Page 2: ...Safety instructions 7 Product description 14 Assembly 16 Use 20 Care maintenance 22 Guarantee 25 Declaration of conformity 26 2...

Page 3: ...1 x1 WARNING Please read all safety warnings carefully and be sure that they are fully understood before handling the tool 3...

Page 4: ...Product description 1 6 1 4 2 3 5 7 8 8a 13 9a 9a 9 10b 10b 10 10a 11 12 4...

Page 5: ...A 7 12 B 8 8a 8 8a C D 8 12 8 8 12 8a E F 11 6 10 5...

Page 6: ...G 1 2 3 G 10b 10b 1 2 1 2 H 10a 10c I J 1 2 9 6 9a 9a 9 2 1 1 K 5 3 2 1 2 6...

Page 7: ...not use any adapter plugs with earthed grounded power tools Unmodi fied plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pi...

Page 8: ...duce dust related hazards h Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles A careless action can cause severe injury within a...

Page 9: ...all times i Ensure that the air vents are always unobstructed and clear Clean them if necessary with a soft brush Blocked air vents may lead to overheating and damage the product j Switch the product...

Page 10: ...t over a period of time not on the odd occasion To protect the lung the COSHH Regulations sets a limit on the amount of these dusts that you can breathe called a Workplace Exposure Limit or WEL when a...

Page 11: ...ght in to help reduce hand arm vibration syndrome injuries to power tool users The directive requires power tool manufacturers and suppliers to provide indicative vibration test results to enable user...

Page 12: ...ING Identify safety measures to protect the operator that are based on an estimation of exposure in the actual conditions of use taking account of all parts of the operating cycle such as the times wh...

Page 13: ...fingers going white as well as specific diseases such as carpal tunnel syn drome To reduce this risk when using the product always wear protective gloves and keep your hands warm RESIDUAL RISKS Even i...

Page 14: ...n in this overview Please refer to the respective section in the instruction manual Symbols the following symbols and abbreviations Familiarize yourself with them to reduce hazards like personal injur...

Page 15: ...logy Built in Anti Vibration Technology Technical data Rated voltage frequency 220 240 V 50 Hz Rated power input 350 W No load speed 6000 12000 min Base plate size 115 x 230 mm Protection class II Wei...

Page 16: ...s also includes suitable personal protective equipment WARNING The product must be fully assembled before operation Do not use a product that is only partly assembled or assembled with damaged parts W...

Page 17: ...nishing cleaning plaster and water stain from wood Only use suitable sanding papers in terms of application and size Do not use the papers that are bigger than the base plate of the product Replace wo...

Page 18: ...ned and loose Pull out old sanding paper and clean the base plate if applicable Fig B 2 Align the hole pattern of the sanding paper 12 with the one in the base plate 7 to ensure efficient dust extract...

Page 19: ...ers 10b and pull the box off Fig G 3 To empty the dust collection box open the window of dust collection box 10c by pressing the release button 10a Fig H External dust extraction device 1 Attach a pro...

Page 20: ...an be controlled by the pressing depth Release the trigger to stop the power tool Continuous mode 1 Switch the product on by pressing the on off switch 2 and hold it in position 2 Press the lock on bu...

Page 21: ...workpieces to prevent them from moving under the product Hold the product with one hand on the front hand grip 1 and with the other hand on the main handle 4 Switch the product on and wait until it ru...

Page 22: ...ir max 3 bar 4 Check for worn or damaged parts Replace worn parts as necessary or contact an authorised service centre for repair before using the product again Do not use chemical alkaline abrasive o...

Page 23: ...must be connected to the terminal which is marked with N or coloured black The wire which is coloured brown must be connected to the terminal which is marked L or coloured red 13 AMP fuse approved to...

Page 24: ...disconnect it from the power supply 2 Clean the product as described above 3 Store the product and its accessories in a dark dry frost free well ventilated place 4 Always store the product in a place...

Page 25: ...ual This guarantee does not cover defects and damage caused by or resulting from Normal wear and tear Overload misuse or neglect Repairs attempted by anyone other than an authorised agent Cosmetic dam...

Page 26: ...ces to the following harmonized standard were made EN 62841 1 2015 EN 62841 2 4 2014 2014 30 EU Electromagnetic Compatibility directive References to the following harmonized standard were made EN 550...

Page 27: ...Electromagnetic Compatibility directive References to the following harmonized standard were made EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 2011 65 EU EU 2015 863 Restrictio...

Page 28: ...3 Sheldon Square London W2 6PX United Kingdom www kingfisher com products Kingfisher International Products B V Rapenburgerstraat 175E 1011 VM Amsterdam The Netherlands Distributor www diy com www sc...