Equflow 6010BCPM Pulse Input Batch Controller Instruction Manual
21
Display
Parameter Action/Setting
Description
Lt-CLr
Latching-
cleared
1
Set relay for latching
operation with manual reset
only after alarm condition
has cleared (relays
assigned to rate)
1
Altern
Alternate
2
Set relay for pump
alternation control (relays
assigned to rate)
2
Sampl
Sampling
Set relay for sampling
operation (rate or GT)
OFF
Off
Disable relay and front
panel status LED
(Select Off to enable
Interlock feature)
Preset
Preset
Set batch preset
Set 1
Set 1
Program set point 1
RSt 1
Reset 1
Program reset point 1
RLY 2
Relay 2
Relay 2 setup.
FaiLSF
Fail-safe
Enter
Fail-safe
menu
FLS 1
Fail-safe 1
Set relay 1 fail-safe
operation
on
On
Enable fail-safe operation
off
Fail-safe off
Disable fail-safe operation
DeLAY
Delay
Enter relay
Time Delay
menu
DLY 1
Delay 1
Enter relay 1 time delay
setup
On 1
On
Set relay 1 On time delay
OFF 1
Off
Set relay 1 Off time delay
break
Loop break
Set relay condition if loop
break detected
(For mA input only)
iGnorE
Ignore
Ignore loop break condition
(Processed as a low signal
condition)
On
On
Relay goes to alarm
condition when loop break
is detected
Display
Parameter Action/Setting
Description
OFF
Off
Relay goes to non-alarm
condition when loop break
is detected
reset
Reset
Press Enter to access the
Reset
menu
Rst Hi
Reset high
Press Enter to reset max
display
Rst Lo
Reset low
Press Enter to reset min
display
Rst HL
Reset
high & low
Press Enter to reset max &
min displays
Rst t
Reset total
Press Enter to reset total
Rst Gt
Reset
grand total
Press Enter to reset grand
total
Rst bc
Reset
batch count
Press Enter to reset batch
count
Contrl
Control
Enter
Control
menu
Auto
Automatic
Press Enter to set controller
for automatic operation
mAn
Manual
Press Enter to manually
control relay operation
`pass
Password
Enter the
Password
menu
Pass 1
Password 1
Set or enter Password 1
Pass 2
Password 2
Set or enter Password 2
Pass 3
Password 3
Set or enter Password 3
Total
Total
password
Set or enter password for
manual reset
Gtotal
Grand total
password
Set or enter password for
manual reset
nonrst
Non-
resettable
Non-resettable grand total
set after entering “050873”
for Gtotal password
unloc
Unlocked
Program password to lock
controller
locd
Locked
Enter password to unlock
controller
999999
-99999
Flashing
display
Overrange condition
Underrange condition
1.
During operation, only STOP button will function, to stop/pause the batch. As a result, relay alarms cannot be manually reset.
2.
This setting is used for level control applications. It is not appropriate if using this controller for batching applications.