9. Troubleshooting
Fault
The tools have been tensioned to their maximum torque value but
the joint will not spread.
Possible Cause
The force required to spread the joint is greater than that of the tools
used.
Corrective
Action
Add another one or two tools and distribute them equally around
the joint (120° apart with 3 tools and 90° apart with 4 tools) and try
again.
Fault
Hoses are connected but the tool does not advance. The pressure
on the pump handle is minimal.
Possible Cause
The release valve is in the retract (open) position
Corrective
Action
Close the release valve .
120
⁰
90
⁰
Close
Release Valve