Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
F
137 136
TM-T90
Specification
(STANDARD)
<Function 49> GS ( K p
L
p
H
fn m (fn = 49)
[Format] ASCII GS ( K p
L
p
H
fn m
Hex 1D 28
4B
p
L
p
H
fn m
Decimal 29
40 75 p
L
p
H
fn m
[Range] (p
L
+ p
H
×
256) = 2 (p
L
= 2, p
H
= 0)
fn = 49
0
≤
m
≤
6, 250
≤
m
≤
255
[Default]
m = 0 (setting value of the customized value)
[Description]
•
Specifies the print density.
m
Print density
250
Standard print density
×
70 %
251
Standard print density
×
75 %
252
Standard print density
×
80 %
253
Standard print density
×
85 %
254
Standard print density
×
90 %
255
Standard print density
×
95 %
0
Standard print density (setting values of GS ( E <Function 5: a = 5>).
1
Standard print density
×
105 %
2
Standard print density
×
110 %
3
Standard print density
×
115 %
4
Standard print density
×
120 %
5
Standard print density
×
125 %
6
Standard print density
×
130 %
[Notes]
•
The print density specified by this function is relative to the print density specified with the
customized value (a = 5) of GS ( E.
•
The range of the absolute ratio of the print density that can be set with the combination of this
function and the customized value (a = 5) of GS ( E <Function 5> is 130% maximum to 70%
minimum.