Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
F
94 93
TM-T90
Specification
(STANDARD)
[Description]
•
Sets the position and the size of the printing area.
•
Horizontal starting position = [(x
L
+ x
H
×
256)
×
(horizontal motion units)].
•
Vertical starting position = [(y
L
+ y
H
×
256)
×
(vertical motion units)].
•
Horizontal printing area width = [(dx
L
+ dx
H
×
256)
×
(horizontal motion units)].
•
Vertical printing area width = [(dy
L
+ dy
H
×
256)
×
(vertical motion units)].
[Note]
•
The maximum printable area is 117.263 mm {1662/360"} maximum.
ESC \ n
L
n
H
[Name]
Set relative print position
[Format] ASCII ESC
\ n
L
n
H
Hex 1B 5C
n
L
n
H
Decimal 27
92 n
L
n
H
[Range] 0
≤
(n
L
+ n
H
×
256)
≤
65535 (0
≤
n
L
≤
255, 0
≤
n
H
≤
255)
[Description]
•
Sets the print starting position based on the current position to ((n
L
+ n
H
×
256)
×
horizontal or
vertical motion units).
•
When (n
L
+ n
H
×
256) is positive number, the print starting position is specified to the right
based on the current position.
•
When (n
L
+ n
H
×
256) is negative number, the print starting position is specified to the left
based on the current position.