EPSON Stylus COLOR 860/1160
Revision C
Adjustment
Adjustment
145
5.2.3.12 Recovery for the clogged nozzle
This function repeats to print the Nozzle check pattern and to perform
the head cleaning. Your can check the recovered nozzle condition after
perform the head cleaning.
NOTE:
In this sequence, CL1’ mode (1.55ml) + rubbiing operation
is always performed.
1.
Choose the “Recovery for clogged nozzle” menu. The following
menu is displayed.
Figure 5-48. Choose the Recovery for clogged nozzle
2.
After set the plain paper, click the “OK” button. The printer performs
the head cleaning sequence and prints the nozzle check pattern as
shown in the next page’s figure.
Figure 5-49. Nozzle Check pattern
3.
After complete one set of the sequence, the program display the
counter that this program is performed as following figure.
Figure 5-50. Display the counter for this program
4.
Depends on the nozzle recovery condition, repeat this program.
Summary of Contents for Stylus COLOR 1160
Page 8: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 28: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 53: ...C H A P T E R TROUBLESHOOTING ...
Page 74: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Page 116: ...C H A P T E R ADJUSTMENT ...
Page 150: ...C H A P T E R MAINTENANCE ...
Page 160: ...APPENDIX C H A P T E R ...