EPSON Stylus COLOR 860/1160
Revision C
Disassembly and Assembly
Disassembly Procedures
115
4.2.4.10 Removing the PE Detector Assembly
1.
Remove the Upper Housing. (Refer to Section 4.2.1.)
2) Remove the ASF Assembly. (Refer to Section 4.2.4.6.)
3) Remove the Right Upper Paper Guide to forward releasing the Torsion
Spring 117.6. Refer to Figure 4-57.
4) Remove the CR Timing Belt and CR Liner Scale (Refer to Section 4.2.4.7.)
5) Disconnect the PE Detector connector from the PE Detector Circuit Board.
Refer to Figure 4-68.
Figure 4-68. Removing the PE Detector connector
6) Using tweezers or a screw driver, release the CR lock lever, and move the
CR unit to the center area of the CR Shaft.
7) Release four fixed hooks securing the PE Detector Assembly from the front
side, and slide the PE Detector Assembly upward to remove.
Figure 4-69. Removing the PE Detector Assembly
PE Detector connector
Back view of the
Printer Mechanism
C H E C K
P O I N T
During assembly, make sure that the tip (sensor part) of the
detector lever is in the hole in the Right Paper Guide Assembly.
Refer to Figure 4-65.
Four hooks fixing the
PE Detector Assy
Summary of Contents for Stylus COLOR 1160
Page 8: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 28: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 53: ...C H A P T E R TROUBLESHOOTING ...
Page 74: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Page 116: ...C H A P T E R ADJUSTMENT ...
Page 150: ...C H A P T E R MAINTENANCE ...
Page 160: ...APPENDIX C H A P T E R ...