SED1520 Series
2–24
EPSON
• MPU Bus Read/Write II (68-family MPU)
Ta = –20 to 75 deg. C, V
SS
= –5 V
±
10 unless stated otherwise
Rating
Parameter
Symbol
Condition
Unit
Signal
Min.
Max.
System cycle time
t
CYC6
1000
—
ns
Address setup time
t
AW6
20
—
ns
A0, CS, R/W
Address hold time
t
AH6
10
—
ns
Data setup time
t
DS6
80
—
ns
Data hold time
t
DH6
10
—
ns
D0 to D7
Output disable time
t
OH6
10
60
ns
C
L
= 100 pF
Access time
t
ACC6
—
90
ns
Enable
Read
100
—
ns
t
EW
E
pulsewidth
Write
80
—
ns
Rise and fall time
tr, tf
—
—
15
ns
—
(V
SS
= –2.7 to – 4.5 V, Ta = –20 to +75
°
C)
Rating
Parameter
Symbol
Condition
Unit
Signal
Min.
Max.
System cycle time
*1
t
CYC6
—
2000
—
ns
Address setup time
t
AW6
40
—
ns
A0, CS, R/W
—
Address hold time
t
AH6
20
—
ns
Data setup time
t
DS6
160
—
ns
—
Data hold time
t
DH6
20
—
ns
D0 to D7
Output disable time
t
OH6
20
120
ns
C
L
= 100 pF
Access time
t
ACC6
—
180
ns
Enable
Read
200
—
ns
t
EW
—
E
pulse width
Write
160
—
ns
Rise and fall time
t
r
, t
f
—
—
15
ns
—
Notes: 1. t
CYC6
is the cycle time of CS. E = H, not the cycle time of E.
t
CYC6
t
EW
t
DS6
t
AW6
E
D0 to D7
(WRITE)
t
r
t
f
t
DH6
t
OH6
t
AH6
D0 to D7
(READ)
t
ACC6
R/W
A0,CS