S5U1C62000A MANUAL
EPSON
201
(S1C60/62 FAMILY ASSEMBLER PACKAGE)
CHAPTER 9: DEBUGGER
ta
(trace area)
Function
This command sets or clears the trace area by the specified program address range.
Format
(1) >ta [<staddr1> <endaddr1> [...... <staddr4> <endaddr4>]]
↵
(direct input mode)
(2) >ta all
↵
(direct input mode)
(3) >ta
↵
(guidance mode)
Current trace area
1. set 2. clear 3. clear all ...? <1 | 2 | 3>
↵
Start address ? <staddr>
↵
End address ? <endaddr>
↵
......
>
<staddr1–4>: Start address of each specified address range; hexadecimal or symbol (IEEE-695 format only)
<endaddr1–4>:End address of each specified address range; hexadecimal or symbol (IEEE-695 format only)
Condition:
0
≤
staddr(1–4)
≤
endaddr(1–4)
≤
last program memory address
Examples
Format (1)
>ta 400 600
↵
... Sets a trace area from address 0x400 to 0x600.
>
Format (2)
>ta all
↵
... Sets as entire program memory to be traced.
>
Format (3)
>ta
↵
Trace area:
0000..0fff
1. set 2. clear 3. clear all ...? 3
↵
... Clears all areas.
>ta
No trace extract address is defined
1. set 2. clear 3. clear all ...? 1
↵
Start address ? 100
↵
... Sets a trace area from address 0x100 to 0x17f.
End address ? 17f
↵
Start address ? 200
↵
... Sets a trace area from address 0x200 to 0x2ff.
End address ? 2ff
↵
Start address ?
↵
... Terminated by [Enter] key.
>ta
↵
Trace area:
0100..017f
0200..02ff
1. set 2. clear 3. clear all ...? 2
↵
Start address ? 150
↵
... Clears a trace area from address 0x150 to 0x24f.
End address ? 24f
↵
Start address ?
↵
>ta
↵
Trace area:
0100..014f
0250..02ff
1. set 2. clear 3. clear all ...?
↵
>
Summary of Contents for S5U1C62000A
Page 4: ......
Page 233: ...S1C62 Family Assembler Package Quick Reference ...