3 FUNCTION OPTION GENERATOR FOG6008
S5U1C60N08D MANUAL
EPSON
13
(DEVELOPMENT SOFTWARE TOOL FOR S1C60N08)
8 R10 specification
*** OPTION NO.8 ***
--- R10 SPECIFICATION ---
OUTPUT SPECIFICATION
1. COMPLEMENTARY
2. P-CH OPEN DRAIN
PLEASE SELECT NO.(1) ? 1
OUTPUT TYPE
1. DC OUTPUT
2. BUZZER OUTPUT
PLEASE SELECT NO.(1) ? 2
OUTPUT SPECIFICATION 1. COMPLEMENTARY SELECTED
OUTPUT TYPE 2. BUZZER SELECTED
Select the output specification for the R10
terminal.
Either complementary output or Pch open drain
output may be selected.
When DC output is selected, R10 becomes a
regular output port. When buzzer output is
selected, by writing "1" to the R10 register, buzzer
drive (oscillation output) signal is output from the
R10 terminal.
*
When DC output is selected, the R13 terminal
output type (see Option 11, "R13 specifica-
tion") selection is limited to DC output only.
The circuit configuration is the same as those of
the output ports R00–R03 (Figure 3.3.3).
Refer to Figure 3.3.6 for the buzzer output
waveform.
Select the output specification for the R11
terminal.
Either complementary output or Pch open drain
output may be selected.
When DC output is selected, R11 becomes a
regular output port. When SIO flag is selected, a
signal indicating the SIO operation status (RUN/
STOP) is generated from the R11 terminal.
The circuit configuration is the same as those of
the output ports R00–R03 (Figure 3.3.3).
9 R11 specification
*** OPTION NO.9 ***
--- R11 SPECIFICATION ---
OUTPUT SPECIFICATION
1. COMPLEMENTARY
2. P-CH OPEN DRAIN
PLEASE SELECT NO.(1) ? 1
OUTPUT TYPE
1. DC OUTPUT
2. SIO FLAG
PLEASE SELECT NO.(1) ? 2
OUTPUT SPECIFICATION 1. COMPLEMENTARY SELECTED
OUTPUT TYPE 2. SIO FLAG SELECTED
10 R12 specification
*** OPTION NO.10 ***
--- R12 SPECIFICATION ---
OUTPUT SPECIFICATION
1. COMPLEMENTARY
2. P-CH OPEN DRAIN
PLEASE SELECT NO.(1) ? 1
OUTPUT TYPE
1. DC OUTPUT
2. FOUT 32768 OR 38400 HZ
3. FOUT 16384 OR 19200 HZ
4. FOUT 8192 OR 9600 HZ
5. FOUT 4096 OR 4800 HZ
6. FOUT 2048 OR 2400 HZ
7. FOUT 1024 OR 1200 HZ
8. FOUT 512 OR 600 HZ
9. FOUT 256 OR 300 HZ
PLEASE SELECT NO.(1) ? 2
OUTPUT SPECIFICATION 1. COMPLEMENTARY SELECTED
OUTPUT TYPE 2. FOUT 32768 OR 38400 HZ SELECTED
Select the output specification for the R12
terminal.
Either complementary output or Pch open drain
output may be selected.
When DC output is selected, R12 becomes a
regular output port. When FOUT is selected, clock
with frequency selected from the R12 terminal is
generated by writing "1" to the R12 register.
•
When DC output is selected
When the R12 register is set to "1", the R12
terminal output goes high (V
DD
), and goes
low (V
SS
) when set to "0".
Output waveform is shown in Figure 3.3.4.
V
DD
V
SS
0
1
0
R12 output
R12 register
Fig. 3.3.4 Output waveform at DC output selection
Summary of Contents for S5U1C60N08D
Page 4: ......