![Epson S5U1C33001H1400 Manual Download Page 26](http://html.mh-extra.com/html/epson/s5u1c33001h1400/s5u1c33001h1400_manual_106865026.webp)
5. CONNECTION
S1C33 Family In-Circuit Debugger
EPSON 21
S5U1C33001H1400 Manual (Rev. 0.20)
30-pin connector
No. Pin
name
I/O Pin
function No.
Pin
name
I/O
Pin function
1
GND
-
Power supply (GND)
16
DST2
I
Bus trace status 2 signal
2
DCLK
I
Clock for debugging
17
DTS1
I
Bus trace status 1 signal
3
GND
-
Power supply (GND)
18
DTS0
I
Bus trace status 0 signal
4
DSIO
I/O Serial I/O signal for debugging
19
GND
-
Power supply (GND)
5
GND
-
Power supply (GND)
20
DTD7
I
Bus trace data 7 signal
6
DST2
I
Debug status 2 signal
21
DTD6
I
Bus trace data 6 signal
7
GND
-
Power supply (GND)
22
DTD5
I
Bus trace data 5 signal
8
DST1
I
Debug status 1 signal
23
DTD4
I
Bus trace data 4 signal
9
GND
-
Power supply (GND)
24
GND
-
Power supply (GND)
10 DST0
I
Debug status 0 signal
25
DTD3
I
Bus trace data 3 signal
11 GND
-
Power supply (GND)
26
DTD2
I
Bus trace data 2 signal
12 DPCO
I
PC signal
27
DTD1
I
Bus trace data 1 signal
13 GND
-
Power supply (GND)
28
DTD0
I
Bus trace data 0 signal
14 DTS4
I
Bus trace status 4 signal
29
GND
-
Power supply (GND)
15 DTS3
I
Bus trace status 3 signal
30
DBT
I
Bus break trigger signal
Notes:
•
The signals connected to the S5U1C33001H are very high-speed signals, so the target connector must be mounted
within 5 cm from the S1C33xxx. If there is more distance between the connector and the S1C33xxx chip, the
S5U1C33001H may not work properly.
•
A
33
Ω
resistor must be connected in series to the DSIO signal line between the connector and the S1C33xxx chip.
The resistor should be placed as close to the S1C33xxx as possible.
•
Be sure to use the supplied 10-pin or 4-pin, or 30-pin cable for Connecting the target system to the S5U1C33001H.
Using another cable may cause a malfunction. Furthermore, do not use the 30-pin cable and 10-pin or 4-pin cable
simultaneously.
•
Disable the trace function of the S5U1C33001H using DIP switch 4 in the following cases:
- when using the 4-pin cable and connector.
- when the signals (DST0, DST1, DPCO) necessary for tracing are not connected even if the 30-pin or 10-pin cable
and connector is used.
- when the trace function is not used due to some reason even if the 30-pin or 10-pin cable and connector is used
and all the signals are connected.
•
The 4-pin connector does not have a projection for preventing reverse insertion. Check the cable marker of pin 1 to be
sure the insertion of connector is proper when connecting it to the target system.
•
The product package does not include a 30-pin cable or the corresponding connector. Please contact us if you need
this cable or the corresponding connector.
Fig. 9 Connecting with 4-pin connectors