4. NAME AND FUNCTION OF EACH PART
12
EPSON
S1C33 Family In-Circuit Debugger
S5U1C33001H1400 Manual (Rev. 0.20)
4.2 Right-side
panel
Fig. 5 Right-side panel
4.2.1 DIP
switch
Note: After operating the DIP switches, press the RESET/START switch to apply the
settings.
•
Selecting target CPU core (SW1)
Table 3-1 DIP SW1 setting
SW1 Setting
OPEN C33
ON
C17 (Not supported)
•
Selecting ICD mode/flash programmer mode (SW2, SW3)
Table 3-2 DIP SW2 and SW3 settings
SW2 SW3
Setting
OPEN OPEN
ICD
mode
ON
OPEN
Flash programmer mode Erase
→
Write
OPEN
ON
Flash programmer mode Verify
ON ON
Flash
mode
Erase
→
Write
→
Verify
ICD mode:
Mode for executing the debug command from the debugger in a PC (see the relevant section)