Confidential
EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
B
RP-U420 series
Specification
(STANDARD)
57
56
ESC c 3 n
[Name]
Select paper sensor(s) to output paper-end signals
[Format]
ASCII
ESC
c
3
n
Hex
1B
63
33
n
Decimal
27
99
51
n
[Range]
0
≤
n
≤
255
[Default]
n
= 0
[Function]
Selects the paper sensor(s) to output paper end signals
•
Each bit of n is used as follows:
Bit
Off/On
Hex
Decimal
Function
Off
00
0
Journal near-end sensor disabled.
0
On
01
1
Journal near-end sensor enabled.
Off
00
0
Receipt near-end sensor disabled.
1
On
02
2
Receipt near-end sensor enabled.
2-7
Off
00
0
Reserved.
[Description]
•
The command is available only with a parallel interface and is ignored with a serial
interface.
•
When all the sensors are disabled, the paper end signal always outputs a paper
present status.