Adjustment
Adjustment
94
5.2.2.5 12.4V (L) Voltage Adjustment
Measuring Point:
CL534
Measuring Equipment:
Digital Voltmeter
ADJ. Location:
VR504
ADJ. Value:
12.40 ± 0.05V
Adjusting Method:
Adjust with VR504 to 12.40 ± 0.05V.
5.2.2.6 7.7V (L) Voltage Adjustment
Measuring Point:
CL563
Measuring Equipment:
Digital Voltmeter
ADJ. Location:
VR505
ADJ. Value:
7.70 ± 0.05V
Adjusting Method:
1.
Use CL554 to check that the pulse width of the inverter clock is
approximately 8.8 msec.
2.
Note that the inverter clock will be at “L” for 1 second after backlight
illumination starts.
3.
Adjust with VR505 to 7.70 ± 0.05V.