5.2.2.6 12.4V (L) Voltage Adjustment 1
SETTING
†
Measuring Point:
CL523 or pin 3 of IC5029
†
Measuring Equipment: Digital voltmeter
†
ADJ.Location:
VR507
†
ADJ. Value:
12.40
±
0.05 V
†
Dial switch:
Play mode
ADJUSTMENT METHOD
1. Adjust with VR507 to 12.4
±
0.05 V
5.2.2.7 12.4V (L) Voltage Adjustment 2
SETTING
†
Measuring Point:
CL523 or pin 3 of Q5029
†
Measuring Equipment: Digital voltmeter
†
ADJ.Location:
VR506
†
ADJ. Value:
12.40
±
0.05 V
†
Dial switch:
LCD shooting mode
ADJUSTMENT METHOD
1. Set the view mode, and turn on the LCD
2. Adjust with VR506 to 12.4
±
0.05 V
5.2.2.8 5.8V (L) Voltage Adjustment
SETTING
†
Measuring Point:
CL530 or pin 4 of Q5033
†
Measuring Equipment: Digital voltmeter
†
ADJ.Location:
VR508
†
ADJ. Value:
5.80
±
0.05 V
†
Dial switch:
LCD shooting mode
ADJUSTMENT METHOD
1. Adjust with VR507 to 5.80
±
0.05 V
Summary of Contents for PhotoPC 800
Page 1: ...EPSONPhotoPC800 Digital Still Camera SEDC99002 6 59 0 18 6 59 0 18 6 59 0 18 6 59 0 18 ...
Page 5: ...Revision Status Revision Issued Date Description A June 10 1999 First Release ...
Page 8: ... 3 7 5 4 PRODUCT DESCRIPTION ...
Page 32: ... 3 7 5 5 OPERATINGPRINCIPLE ...
Page 52: ... 3 7 5 6 TROUBLESHOOTING ...
Page 55: ... 3 7 5 7 DISASSEMBLYANDASSEMBLY ...
Page 74: ... 3 7 5 8 ADJUSTMENT ...
Page 90: ... 3 7 5 9 MAINTENANCE ...
Page 92: ... 3 7 5 APPENDIX ...
Page 94: ......
Page 96: ...ca1_pcb ...
Page 97: ...ca2_pcb ...
Page 98: ...sy1_pcb ...
Page 99: ...pw1_pcb ...
Page 101: ......
Page 102: ...NTSC ...
Page 103: ...PAL ...
Page 104: ......
Page 105: ......
Page 110: ......