EPSON PhotoPC 800
Revision A
Adjustment
Adjustment
79
5.2.2 Positions for measuring and adjusting on the
PW1 Board
When replacing the PW1 board, it is not necessary to perform this adjustment.
However, it is required to perform this if you replace any parts of PW1 board.
Figure 5-5. Positions for measuring and adjustment
PREPARATION
1.
Connect CN104 on the CA2 board and CN502 on the PW1 board with
extension cord.
2.
Open the barrier switch.
3.
Set the view mode, and turn on the LCD.
4.
Carry out initialization and display the through image on the LCD screen.
5.2.2.1 IC501 Oscillation Frequency Adjustment
SETTING
†
Measuring Point:
CL512
†
Measuring Equipment: Frequency counter
†
ADJ.Location:
VR501
†
ADJ. Value:
200
±
1 kHz
†
Dial switch:
LCD shooting mode
ADJUSTMENT METHOD
1. Adjust with VR501 to 200
±
1 kHz
C A U T I O N
„
Voltage adjustment is necessary to repair in the PW1
board and replace the parts.
„
Power voltage is set about +3.0 V.
VR505
CL533
CL518
CL536
VR504
VR503
VR508
VR502
VR501
VR506
VR507
CL512
Q5008 (C)
Q5033-4
CL523
CL537
CL534
CL532
CL530
Q5029-3
Summary of Contents for PhotoPC 800
Page 1: ...EPSONPhotoPC800 Digital Still Camera SEDC99002 6 59 0 18 6 59 0 18 6 59 0 18 6 59 0 18 ...
Page 5: ...Revision Status Revision Issued Date Description A June 10 1999 First Release ...
Page 8: ... 3 7 5 4 PRODUCT DESCRIPTION ...
Page 32: ... 3 7 5 5 OPERATINGPRINCIPLE ...
Page 52: ... 3 7 5 6 TROUBLESHOOTING ...
Page 55: ... 3 7 5 7 DISASSEMBLYANDASSEMBLY ...
Page 74: ... 3 7 5 8 ADJUSTMENT ...
Page 90: ... 3 7 5 9 MAINTENANCE ...
Page 92: ... 3 7 5 APPENDIX ...
Page 94: ......
Page 96: ...ca1_pcb ...
Page 97: ...ca2_pcb ...
Page 98: ...sy1_pcb ...
Page 99: ...pw1_pcb ...
Page 101: ......
Page 102: ...NTSC ...
Page 103: ...PAL ...
Page 104: ......
Page 105: ......
Page 110: ......