When Having Some Trouble
34
: lit
: flashing
Internal problem
Stop using the projector, disconnect the power cable from
the electrical outlet, and contact your dealer or the nearest
address provided at "International Warranty Conditions"
in Safety Instructions/World-Wide Warranty Terms.
High-speed
cooling in
progress
(This is not an abnormality, but if the temperature rises too
high again, projection will stop automatically.)
••••
Set the projector up in a place which is well-ventilated,
and so that the air filter and exhaust vents are clear.
••••
Clean the air filter.
Setup Guide
p.44
Power Indicator
Status
Cause
Remedy or Status
See Page
Standby status
(Not abnormal)
The power cable should only be disconnected when the
projector is in this condition.
Press the [Power] button to start projection.
p.6
Cool-down in
progress
(Not abnormal)
••••
Please wait.
The cool-down
period lasts for about 20 seconds.
••••
The [Power] button does not work during cool-down.
Press the button again after cool-down ends.
p.9
Projection in
progress
(Not abnormal)
p.7
Warm-up in
progress
(Not abnormal)
Please wait.
Warm-up time is approximately 40 seconds.
After warm-up is complete, the flashing green indicator
changes to steady green.
p.7
••••
If the projector is not operating properly even though the indicators are all showing normal, refer
to "When the Indicators Provide No Help" on the following page.
••••
If an indicator is showing a status which does not appear in the previous tables, contact your
dealer or the nearest address provided at "International Warranty Conditions" in
Safety
Instructions/World-Wide Warranty Terms.
Status
Cause
Remedy or Status
See Page
Red
(1-second
intervals)
Orange
Orange
Orange
Green
Green
(Warning) Indicator
Power Indicator
Summary of Contents for EMP-30
Page 1: ......
Page 5: ...3 ...
Page 6: ......
Page 44: ......
Page 68: ...Printed in Japan 404003503 02 09 2 4A C05 Printed on 100 recycled paper E ...