31
After installing the projector on the ceiling, pass
the 4 wires provided diagonally through the
projector using the wire clips to prevent the
projector from falling.
A
Locate the four commercially available
anchor bolts on the ceiling at each
corner of the projector.
We recommend locating the anchor bolts
within 1 meter from the center of the
projector.
Use M12 anchor bolts.
B
Loop the four safety wires around the
four bolts and secure them firmly.
Make sure that the wire loops are under the
flat washers, and then tighten the hexagon
nuts.
Installing the Safety Wires
Procedure
v
Make sure in advance that the concrete on which this product is installed can
hold the weight and lateral movement of the projector and ceiling mount. If the
concrete is not strong enough or has deteriorated, fortify it with reinforcing
bars or something similar.
v
Install the anchor bolts according to the specifications and methods of the
manufacturer of the materials so they do not come out, become loose, or shift.
Warning
Anchor bolt (M12)
Within 1m
(recommended)
Within 1m
(recommended)
Safety wire
Anchor bolt
Flat washer
(
φ
24 -
φ
26mm)
Spring
washer
Hexagon nut
Summary of Contents for ELPMB26