25
C
There are six length adjustment holes at
20 mm intervals on the pole. Align the
two appropriate adjustment holes with
the holes for the fixing bolts, and put the
two fixing bolts into the holes and
tighten them firmly.
D
Tighten the four assist-screws on both
sides using the M6 wrench.
Mounting to a Concrete Ceiling
When installing the ceiling mount on a concrete ceiling, use 4 anchor bolts (M12). You need
to purchase commercially available anchor bolts.
v
Make sure in advance that the concrete on which this product is installed can
hold the weight and lateral movement of the projector and ceiling mount. If the
concrete is not strong enough or has deteriorated, fortify it with reinforcing
bars or something similar.
v
Install the anchor bolts according to the specifications and methods of the
manufacturer of the materials so they do not come out, become loose, or shift.
v
Tighten the screws firmly during installation or after adjusting the angles.
After tightening the screws, retighten them firmly and make sure that they are not
loose.
v
Epson accepts no responsibility for the projector and the ceiling mount falling
due to inadequate installation.
Warning
Female type anchors
Concrete
Hanger bolts
Spring washers
Hexagon nut
At least 3 threads
Ceiling surface
Flat washers
Hexagon nut
Summary of Contents for ELPMB26