background image

Max Load Capacity:

 200 lb (91 kg)

Installation and Assembly:

Dedicated Tilt Wall Mount

Model:

 ST16D

ISSUED: 09-15-05  SHEET #: 202-9031-3  08-18-11 

2300 White Oak Circle  •  Aurora, Il 60502  •  (800) 865-2112  •  Fax: (800) 359-6500  •  www.peerlessmounts.com

Summary of Contents for SmartMount ST16D

Page 1: ...city 200 lb 91 kg Installation and Assembly Dedicated Tilt Wall Mount Model ST16D ISSUED 09 15 05 SHEET 202 9031 3 08 18 11 2300 White Oak Circle Aurora Il 60502 800 865 2112 Fax 800 359 6500 www peerlessmounts com ...

Page 2: ...upport the combined load of the equipment and all attached hardware and components Never exceed the Maximum Load Capacity of 200 lb 91 kg If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten...

Page 3: ...36 B wall plate 1 200 1797 C 14 x 2 5 wood screw 4 5S1 015 C03 D concrete anchor 4 590 0320 E M10 x 15 mm socket head screw 4 520 9262 F 4 mm security allen wrench 1 560 1146 Parts List Parts may appear slightly different than illustrated Before you begin make sure all parts shown are included with your product B ...

Page 4: ...sing three 14 x 2 5 wood screws C as shown in figure 1 2 Skip to step 2 on page 7 B C fig 1 1 fig 1 2 2 5 64 mm CS center of screen CS Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws g...

Page 5: ...all plate is level secure it using four 14 x 2 5 wood screws C as shown in figure 1 4 Skip to step 2 on page 7 C B fig 1 4 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reduc...

Page 6: ... void or cavity Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components WARNING 1 3 D Drill holes and insert anchors D Place plate B over anchors C and secure with screws D Tighten all fasteners 2 D B C concrete surface Tighte...

Page 7: ...ews E Note Full tilt bracket assembly not shown for clarity Skip to step 3 2 Attaching PLP Adapter Plate to Tilt Bracket Assembly Note Refer to accompanying instruction sheet for attachment of adapter plate to screen before proceeding with step 2 E ADAPTER PLATE A NOTE INTERFACE BRACKET SHOWN WITHOUT FULL TILT BRACKET ASSEMBLY FOR CLARITY ...

Page 8: ...C Adapter Plate to Tilt Bracket Assembly GENERIC LC ADAPTER PLATE M5 SCREWS Note Refer to accompanying instruction sheet for attachment of adapter plate to screen before proceeding with step 2 Tighten screws so interface bracket is firmly attached Do not tighten with excessive force Overtightening can cause stress damage to screws greatly reducing their holding power and possibly causing screw hea...

Page 9: ... detail 1 If mount is attached to double wood stud solid concrete or cinder block wall screen can be adjusted horizontally if desired If mount is attached to single wood stud wall screen must be centered on wall plate B To remove screen from mount loosen security screws swing screen away from mount and lift screen off of mount DETAIL 1 SECURITY SCREWS B B A A 3 Always use an assistant or mechanica...

Page 10: ...t shown in figure 4 2 and detail 3 using wrench F fig 4 1 4 DETAIL 2 Adjusting the Tilt Angle of the Flat Panel Screen 2011 Peerless Industries Inc All rights reserved All other brand and product names are trademarks or registered trademarks of their respective owners Peerless Industries Inc 2300 White Oak Circle Aurora Il 60502 www peerlessmounts com Do not tighten screws with excessive force Ove...

Page 11: ...or repairs by Peerless b the failure to utilize proper packing when returning the product c incorrect installation or the failure to follow Peerless instructions or warnings when installing using or storing the product or d misuse or accident in transit or otherwise including in cases of third party actions and force majeure In no event shall Peerless be liable for incidental or consequential dama...