EPL-9000
Service Manual
Troubleshooting
Table 5-39. Print Quality Problems (Continued)
Symptom
Possible Cause
Part Name
Cheek Item
Remedy
line
Window of optical Optical unit
—
unit is dirty.
Clean the window.
I
Poor image
transfer
roller
—
Replace the
roller.
Imaging
Replace the imaging
cartridge
—
cartridge.
Dirt on the fusing
Fusing
—
Replace the fusing
roller
roller.
line
Poor image
transfer
roller
—
Replace the
roller.
n
Imaging
Replace the imaging
PRINTER
cartridge
—
cartridge.
Dirt on the
Fusing
—
Replace the fusing
roller
roller.
Paper feed is bad . Drive unit
—
Replace the drive unit.
line
Window of optical
Optical unit
—
unit is dirty.
Clean the window.
Poor image
transfer
roller
—
Replace the
roller
Imaging
Replace the imaging
TER
cartridge
—
cartridge.
Clean the charge wire
Improper
Charge wire
—
of the imaging
charging
cartridge. (Refer to
chapter 6.)
paper separation
Trans. chute
—
replace the trans.
is bad.
fan
chute fan.
Dirt on the fusing
Fusing
—
Replace the fusing
roller
roller.
Black line
Poor image
transfer
roller
—
Replace the
roller
Imaging
Replace the imaging
cartridge
—
cartridge.
Dirt on the
9
Replace the fusing
roller
roller.
Rev.
5-15