EPSON AcuLaser C2600/2600
Revision B
Troubleshooting
Printing-quality troubleshooting (PQT)
196
PQT-10: VERTICAL COLOR STREAKS OR BANDS
Symptom
PQT-11: VERTICAL LUSTERED STREAKS OR BANDS
Symptom
The position is different between the four colors, or
appear only on a certain color.
No.
Cause
Check Point
Defect Parts
1
Toner Cartridge failure
(e.g. the control blade
gets chipped)
Replace the Toner cartridge.
Toner cartridge
PQT_009
Lustered streaks or bands appear on a printed image. It
tends to appear on a high density area of an image
other than area near leading edge of a paper. They may
be traces of the thermistor of the fuser roller caused by
wear of the fuser roller.
No.
Cause
Check Point
Defect Parts
1
105 mm from the left
edge of paper = Trace of
thermistor
Replace the Fuser unit.
Fuser unit
2
Other = Trace of rib on
the PR Separator
Replace the Fuser unit.
Fuser unit
PQT_010
Summary of Contents for Aculaser 2600 Series
Page 1: ...EPSON AcuLaserC2600 2600 A4 Full Color Laser Printer SERVICE MANUAL SEPG04005 ...
Page 12: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 85: ...C H A P T E R 2 OPERATINGPRINCIPLE ...
Page 141: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 209: ...EPSON AcuLaser C2600 2600 Revision B Troubleshooting Test Print 209 PRINTED PATTERN 03003101 ...
Page 210: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 364: ...C H A P T E R 5 ADJUSTMENT ...
Page 384: ...C H A P T E R 6 MAINTENANCE ...
Page 410: ...C H A P T E R 7 APPENDIX ...
Page 437: ...EPSON AcuLaser C2600 2600 Revision B APPENDIX Exploded Diagrams 437 7 4 Exploded Diagrams ...
Page 450: ...Model AcuLaser C2600 AcuLaser 2600 Board C585 MAIN Sheet 1 of 5 Rev B ...
Page 451: ...Model AcuLaser C2600 AcuLaser 2600 Board C585 MAIN Sheet 2 of 5 Rev A ...
Page 452: ...Model AcuLaser C2600 AcuLaser 2600 Board C585 MAIN Sheet 3 of 5 Rev A ...
Page 453: ...Model AcuLaser C2600 AcuLaser 2600 Board C585 MAIN Sheet 4 of 5 Rev B ...
Page 454: ...Model AcuLaser C2600 AcuLaser 2600 Board C585 MAIN Sheet 5 of 5 Rev B ...