EPS 1001905 Operation And Maintenance Manual Download Page 7

7

7

Delivery and Handling

The Multiboost system is supplied from the factory, as an all-in-one packaged water boosting 

system. The weight and size of the Multiboost (depending on model chosen) may require 

the aid of lifting equipment and if so, must be handled in a safe and proper manner to 

avoid causing unnecessary damage to the unit and/or individual/s. In the event that lifting 

equipment is used, please follow widely accepted safe lifting procedures.

Inspection

On delivery, the Multiboost should be inspected thoroughly and any damage must be 

reported to the supplier in writing within 24/48 hours. Always ensure the Multiboost 

inspection takes place prior to installation.

Applications

The Multiboost set is designed to be compact, with ease of installation, and to provide many 

years of service for domestic pressure boosting and light commercial pressure boosting. 

The Multiboost set should not be installed in areas that are classified as hazardous, where 

an explosion could occur or people could be harmed or in an area of any potential leaks that 

could cause damage to any person or property. The use of bunded tanks and/or a drip tray are 

essential to any Multiboost being installed above ceiling level. 

EPS accepts zero responsibility if the Multiboost is used to pump liquids that are considered 

hazardous by touch, ingestion or inhalation of fumes or gases given off by the liquid, or any 

damage caused to property where the recommended protection of a drip tray or use of 

bunded tank was not adhered to.

Warranty

Your Multiboost system is covered by a 12 month warranty from the date of purchase. This 

warranty covers all parts or material defects and will be replaced free of charge. Labour call 

outs for warranty / repair will require a call out fee of €150 incl. VAT. This fee must be paid 

up front to secure call out. If there is a warranty defect with the unit, it will be repaired / 

replaced and your €150 will be refunded. If there is a defect outside EPS’ control (i.e. incorrect 

installation) the €150 fee will not be refunded. The additional cost of replacement parts will be 

administered in this situation also. EPS cannot carry out any tests, servicing or repairs on a unit 

if the drip tray has not been fitted as part of the unit being installed in the property.

Site Storage

Once a Multiboost has arrived on site and has been inspected, it is recommended that it is 

stored away from sharp objects, in a safe place, on an even surface, free from moisture, dust, 

sunlight and frost.

Pre Installation Checks

Please ensure the unit is fitted and supported in the right manner. Check the unit for any visual 

defects.

In accordance with the latest IEE regulation, all electrical connections should be carried out 

by a qualified electrician. The Multiboost must be earthed. EPS strongly recommend that 

a correctly sized RCBO for fixed speed and MCB for variable speed units are fitted on the 

incoming electrical supply. If the installer is fitting a plug, please ensure the correct fuse is 

selected in relation to the pump selection ampage. Please see page 13 for more information.

Delivering, Handling and Storing

Multiboost Range

• Please ensure that Presflo Multi system is fitted with the correct rated RCBO on incoming electrical supply

• Please ensure that the Steadypres is fitted with the correct rated MCB on incoming electrical supply

Summary of Contents for 1001905

Page 1: ...MULTIBOOST O M Manual Rev 4 Integrated Sanic UV System Multiboost Installation Dos Donts...

Page 2: ...g 7 Installation Guide Schematics 8 Key Features 13 Drip Trays 14 Electrical 15 Pump Type Control Information 16 Fixed Speed Presflo Multi Controls 17 Presflo Multi 18 Presflo Vario 19 Steadypres 20 A...

Page 3: ...documents Refer to page 4 for list of national implementation provisions I hereby declare that the equipment above has been designed and assembled to comply with the relevant section of the above refe...

Page 4: ...compliances RoHS 2002 96 CEE e 2003 108 CEE Dangerous substances in electronic appliances WEEE 2004 108 CE Electromagnetic Compatibility Directive EMC EN 5501 1 emissions Provisions EN 61000 3 2 emis...

Page 5: ...ngth MM Width MM Height MM Inlet Inch Outlet Inch Over flow Inch Drain o Inch Weight Empty Tank kg 1031919 MULTIBOOST 350L Simplicity Slimline Fixed Speed Vario 350 584 584 1260 BSP 1 BSP 1 BSP 1 BSP...

Page 6: ...ular Utility Fixed Speed 500 1190 720 800 BSP 1 BSP 1 BSP 1 BSP 34 1017488 MULTIBOOST 300L Rectangular Multi Fixed Speed Presflo 300 1045 665 710 BSP 1 BSP 1 BSP 1 BSP 29 1070476 MULTIBOOST 455L Recta...

Page 7: ...ction of a drip tray or use of bunded tank was not adhered to Warranty Your Multiboost system is covered by a 12 month warranty from the date of purchase This warranty covers all parts or material def...

Page 8: ...ipe may have to be further increased in size and EPS recommends the installer fully tests this system to ensure that the overflow pipe is capable and adequate to cope with the unlikely event of a fail...

Page 9: ...nes and recommendations have been considered Please refer to Commissioning Checklist Foundation Mounting Multiboost must be mounted on a solid foundation to support the weight of the unit Surfaces mus...

Page 10: ...ressure and flow and should be piped away to safe drainage zone It s recommended that a full test is carried out by the installer Overflow test to be completed after every installation This is to ensu...

Page 11: ...drip tray over flow Multiboost drain off Drip tray 2 3 4 5 6 7 Removable lid with pump 8 controller inbuilt Multiboost 200L 270L 345L and 455L EPS recommends the use of a drip tray and insulation jack...

Page 12: ...3 6 7 5 2 1 4 EPS recommends the use of a drip tray and insulation jacket with every installation 1 Ball cock Isolation valve with pressure gauge Bypass isolation valve Multiboost overflow Multiboost...

Page 13: ...ectedmodelsonly 4 3 5 Easy adjustable cut in pressure function 6 Variable speed option available 5 7 Vermin screen 7 8 Ball cock unit float 8 9 Drain off facility to clean tank 9 10 Overflow 11 Inlet...

Page 14: ...D E E F F STBL00500R 285mm Lid 1 Connection STBL00300R 190mm Lid 1 Connection STBL00200R One Lid Only 1 Connection STBL00270R One Lid Only 1 Connection EPS Tanks Drip Trays Rev No R1 0 Rev Date 08 02...

Page 15: ...m 2 3 UPm 2 3 Pump 230V 5 4 Amps NKm 2 4 UPm 2 4 Pump 230V 6 2 Amps Commissioning Carry out a visual check to make sure all pipe work and electrical connections are connected in a safe manner Fill the...

Page 16: ...from drip tray Outlet 3 3 6 7 5 2 1 4 EPS recommends the use of a drip tray and insulation jacket with every installation 1 Ball cock Isolation valve with pressure gauge Bypass isolation valve Multibo...

Page 17: ...arately without any sharp edges which could cause restriction Yes No Has incoming water pressure been tested and has the correct ballcock been selected and tested Yes No Has the Multiboost been fitted...

Page 18: ...ith density 1 0 kg dm3 and kinematic viscosity 1mm2 s Date Approved by Enrico Vandin TOP MULTI 2 50Hz TEST REPORT EN ISO 9906 Grade 3B 23 09 2015 45 46 47 48 49 50 51 52 53 54 55 0 10 20 30 40 50 60 7...

Page 19: ...d between 4A and 16A Manufacturer s setting PRESFLO is supplied with the following STANDARD CONFIGURA TION Running pressure Pm 2 bar Max current allowed I max 16 A Configuration The adjustment of the...

Page 20: ...start manually See Oper ation point 4b Remove any cause of leakage from system or install an expansion tank POWER ON PUMP ON PRESFLO stops due to OVER CURRENT Check if the setting of the maximum curre...

Page 21: ...ess START to restart manually See Oper ation point 4b Remove any cause of leakage from system or install an expansion tank The pump delivers no or low pressure POWER STATUS Filters or pipes may be par...

Page 22: ...15 make sure the motor pump is turning freely and is not braked check the correct direction of rotation check the correct sizing of the wires CURRENT LIMIT Serious overcurrent absorption which invert...

Page 23: ...sor fault Check the display pressure with a reference manometer re calibrate or substitute the pressure sensor PROBLEM Pump always running even when not required Message Cause Intervention None System...

Page 24: ...noise Key Features Improvement of impact sound Lw 18dB Reduce dB vibration levels Easy to install Simple processing cutting drilling Various sizes available for each model Anti Vibration Mats MODEL S...

Page 25: ...an help prevent water from freezing and will also reduce the operating dB level of the unit We highly recommend using these insulated jackets Key Features Various sizes available for each model Reduce...

Page 26: ...We highly recommend using these insulated jackets Key Features Various sizes available for each model Reduce dB vibration levels Easy to install Simple process for installer Extra protection for extre...

Page 27: ...F F STBL00500R 285mm Lid 1 Connection STBL00300R 190mm Lid 1 Connection STBL00200R One Lid Only 1 Connection STBL00270R One Lid Only 1 Connection EPS Tanks Drip Trays Rev No R1 0 Rev Date 08 02 2019...

Page 28: ...04953 Multi Stage UV Filtration Flowrateupto23L minat30mJ cm2 Flowrateupto40L minat16mJ cm2 Ultra violet disinfection Odour removal Enclosed cabinet plug and play Product Code 1019182 Drip Tray Slimli...

Reviews: