Version 3.0
COPYRIGHT © 2012 Red.com, Inc.
955-0002_v3.0, Rev-B
212
212
RED Focus Properly Installed on Camera
4.
Power up the camera.
5.
Power up RED Focus. Refer to POWER UP / DOWN.
NOTE: Remember that RED Focus will AUTOMATICALLY power down after 3 minutes. Press
the Red button on the front to power back up.
6.
Set the camera to Magnify. Go to SECONDARY MENUS > SETTINGS > DISPLAY > FALSE COLOR
> MAGNIFY.
NOTE: The “Focus” option located under SECONDARY MENUS > SETTINGS > DISPLAY >
FALSE COLOR > FOCUS can serve as a good double-check for proper focus during this
procedure.
RED Focus Displayed Image on Camera
7.
Insert a T-10 Torx
®
screwdriver into the back focus adjustment screw. The screw is oriented at
approximately 80° as shown.
Performing Back Focus Adjustment
8.
Carefully and slowly, rotate the back focus adjustment screw to achieve optimum focus.
-
Turning CLOCKWISE moves the sensor forward.
Summary of Contents for Epic-M