12
1) Connect components to the charge controller in the sequence as shown above
and pay much
attention to the ―+‖ and ―-‖.
Please don‘t turn on the fuse during the
installation. When disconnecting the system, the order will be reserved.
2) After installation, power the controller and check the battery indicator on the
controller, it will be green. If it‘s not green, please refer to chapter 4. Always connect
the battery first, in order to allow the controller to recognize the system voltage.
3) The battery fuse should be installed as close to the battery as possible. The
suggested distance is within 150mm.
4)
The Tracer-BN series is a negative ground controller. Any negative connection of
solar, load or battery can be earth grounded as required.
CAUTION:
Unplug the RTS, the temperature of battery will be set to a
fixed value 25 ºC.
CAUTION:
Please connect the inverter to the battery rather than to the
controller, if the inverter is necessary.
CAUTION:
The RS-485 port and RTS port is not SELV circuit, it must
have isolation between the port and the place where the end user can
access directly.