REV. 12/2020
5
C
All the batteries are maintenance free.
Battery types & dimensions are as follows:
Tuck type
voltage/
rated
capacity
Dimension
Charger
Charging
time
EST122
2x12/85
260x165x210
10A
8h
1.2.2
Battery type & dimensions &
Charging time
1.2.3 Handling of the battery acid
Do not deep dicharge battery:
If you discharge the battery completely till the trucks do not move any more, you will shorten the
service time of the battery.
As soon as the signal for charging appears, no more lifting or travelling, please charge it
immediately.
Battery maintenance:
The battery cell covers must be kept dry and clean. The terminals and cable shoes must be
clean, secure this with a light coating of dielectric grease. Batteries with non insulated terminals
must be covered with a non slip insulation mat.
Cleaning the battery
Do not use dry cloth or fibre cloth to clean the battery to prevent static charging and explosion.
Unfix battery plug.
Clean with wet cloth.
Wear glasses to protect eyes, wear rubber overshoes and rubber gloves.
Battery Disposal
Batteries must only be disposed of as stipulated in the national environmental protection
regulations or waste disposal provisions. The battery manufacture’s specifications for the
disposal must be followed.