23
GB
3.4. Error messages and troubleshooting
Please inform our Service Center should the non-removable error messages F1 - F5 occur.
Error
Cause
Remedy
F1
Sensor breakage
Check the sensor circuit.
If necessary, replace the sensor
F2
Temp. over 130°C,
Sensor defective
Check the sensor circuit
If necessary, replace the sensor
F3
Temp. up to 106°C,
Device calcified,
Water level elec-
trode defective,
Water foaming,
Overpressure in tank
Check the water tank for scale.
Check the water level electrode.
Allow the device to cool down and carry out a RESET,
(disconnect the device temporarily from the mains).
Check for possible foaming (e.g. because of fra-
grances) and rinse the tank thoroughly.
Check for possible overpressure (steam pipe blocked).
F5
Descaler con-
tainer empty
Replenish the descaler container with descaler liquid
3.3.2 Maintenance
Maintenance of the unit should take place twice per year on public systems.
Maintenance of the unit should take place once per year on private systems.
During maintenance, the tank hoses and the drain, amongst other things, should be
inspected.
Summary of Contents for SteamTec Premium
Page 2: ...2 Deutsch 3 English 15 27...
Page 28: ...28 RU 1 5 13 45 SteamTec Premium T1 T3 T7 T5 T2 T4 RGB T8 T6 SteamTec Premium T1...
Page 32: ...32 RU P0 00 01 02 14 14 RGB 00 02 P1 00 01 15 15 00 01 P2 05 05 20...
Page 33: ...33 RU 2 100 C 15 20 42 45 C...
Page 34: ...34 RU 3 1 3 30 E 35 E 35 100 30 35 T1 F5 1 50...
Page 35: ...35 RU P5 00 P5 01 30 P9 10 20 30 E 35 E 35 3 2 3 3 3 3 1 EOS 3 2 1...
Page 36: ...36 RU 3 4 F1 F5 F1 F2 130 C F3 106 C F5 3 3 2 2 1...
Page 39: ...39 RU RMA RMA RMA 3 2 2 RMA 1...