19
GB
If PA = 01 is selected in the program step of the service programming, the generator is
switched into Stand-by after 4 hours of operation. The generator can be put back into
operation by pressing the T1 generator key or by switching the janitor switch off and
then back on again.
In program step PA = 02, the runtime limitation takes place to 30 min. and for
PA = 03 to 45 min.
If the programming step PA = 00 is selected in the service programming, the generator
does not automatically switch into Stand-by.
1.11 Runtime limitation
1.12. Customer programming
13:45
SteamTec
Premium
T1
T3
T7
T2
T4
T8
1. By pressing the T2 and T4 keys for ap-
prox. 5 s, the controls will switch to the
function "Customer programming".
2. On the left-hand half of the display, the
program step P0 will appear, and in the
right-hand half of the display, the preset
parameter value e.g. 02 will appear.
3. The program step can be switched with
the T1 or T3 key from P0 – P2.
4. The parameters can then be set with the
+/- key.
5. After finishing programming, leave this
level by simultaneously pressing buttons
T2 and T4 again.
The following parameters can be set by the user:
Program step
Parameter
Function
Setting range
P0
00
01
02
Relay 14 off
Relay 14 on
on/off via RGB-button
00 - 02
P1
00
01
Relay 15 off
Relay 15 on
00 - 01
P2
05
After-run time
Waste air
05 20 min.
T5
T6
Summary of Contents for SteamTec Premium
Page 2: ...2 Deutsch 3 English 15 27...
Page 28: ...28 RU 1 5 13 45 SteamTec Premium T1 T3 T7 T5 T2 T4 RGB T8 T6 SteamTec Premium T1...
Page 32: ...32 RU P0 00 01 02 14 14 RGB 00 02 P1 00 01 15 15 00 01 P2 05 05 20...
Page 33: ...33 RU 2 100 C 15 20 42 45 C...
Page 34: ...34 RU 3 1 3 30 E 35 E 35 100 30 35 T1 F5 1 50...
Page 35: ...35 RU P5 00 P5 01 30 P9 10 20 30 E 35 E 35 3 2 3 3 3 3 1 EOS 3 2 1...
Page 36: ...36 RU 3 4 F1 F5 F1 F2 130 C F3 106 C F5 3 3 2 2 1...
Page 39: ...39 RU RMA RMA RMA 3 2 2 RMA 1...