Dear customer
You have purchased a high-quality technical 

device with which you will have years of sau-

na fun. This sauna heater was designed and 

inspected according to the current European 

safety standards and manufactured at the facto-

ry in accordance with the quality management 

standard DIN EN ISO 9001:2008.
This detailed installation and operation manual 

has been prepared for your information. Please 

observe in particular the 

important notes

 and 

the information on electrical connection.
We wish you exhilarating recreational experience 

and lots of fun with your sauna!

Intended use

This sauna heater is exclusively intended for the 

heating of sauna cabins in combination with an 

appropriate control unit. 

Any other use over and above the intended 

purpose is not considered as appropriate use! 

Compliance of the standard operation, mainte-

nance and repair conditions is also an element 

of appropriate use.

The manufacturer cannot be held liable for 

deviating, unauthorized alterations and any re-

sulting damages: the initiator of these changes 

bears the full risk.

General information

Please check whether the unit has arrived in per-

fect condition. Any transport damages should be 

immediately reported to the freight forwarder 

delivering the goods or you should contact the 

company that shipped the goods. 

Please note that you will only be able to achieve 

an optimum sauna climate if the cabin with its air 

intake and ventilation, the sauna heater and the 

control unit are aligned to each other.

Please observe the information and stipulations 

made by your sauna supplier.

Sauna heaters heat up your sauna cabin using 

heated convective air. Here, fresh air is drawn 

in from the air intake which, when heated, rises 

upwards (convection) and is then circulated 

within the cabin. Part of the used air is pushed 

out through the vent in the cabin. This creates a 

typical  sauna climate which can achieve tempe-

ratures of approx. 110°C measured directly under 

the ceiling of your sauna, dropping in tempera-

ture to approx. 30-40°C towards the floor. It is 

therefore not unusual to measure temperatures 

of 110°C on the temperature sensor hanging 

over the heater, whilst the thermometer hanging 

on the sauna wall, approx. 20-25 cm under the 

cabin ceiling, only indicates 85°C. The bathing 

temperature generally lies between 80°C and 

90°C in the area of the upper bench when the 

temperature is set to maximum.

Please note that the highest temperatures are 

always generated over the sauna heater and that 

the temperature sensor and the safety limiter 

must be mounted there in accordance with the 

control unit installation instructions.

When heating up for the first time, you may 

notice a slight  smell caused by evaporating 

lubricants used in production processes. Please 

ventilate your cabin before beginning your 

sauna bath.

Summary of Contents for Filius Control

Page 1: ...INNOVATIVE SAUNA TECHNOLOGY MADE IN GERMANY Druck Nr 29345062 en 18 19 Filius Control 400 V 3N AC 230 V 1N AC EN Installlation and operating instruction...

Page 2: ...ications 6 Connection example 400 V 3N 8 Connection example 230 V 1N 9 Installation of the Filius Control 10 Minimum distances 10 Commissioning 12 Position change control panel left right 13 Replaceme...

Page 3: ...pped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please...

Page 4: ...eofsuitable low resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each saun...

Page 5: ...floor On heaters with bases this clearance is maintained via the base or legs of the device Floor heating in the sauna cabin increases the surface temperature of the flooring Please see the dimension...

Page 6: ...able exits the sauna heater and guide this cable outside through the hole to the control unit The cable and all other connecting cables mains power cables and cabin lighting should be installed in ins...

Page 7: ...AC Anschluss an 230V 1NWechselstrom m glich Power rating 4 5 kW 6 0 kW 7 5 kW For sauna size 4 6 m 6 8 m 7 10 m Min size air inlet and exhaust vent 35 x 11 cm Weight without stones and packing 15 kg...

Page 8: ...ite Connection example for 400V 3N AC 4 5 kW 3x 1500 W 6 0 kW 3x 2000 W 7 5 kW 3x 2500 W Power acc DIN Electrical connection Fuse protection Connecting cable main heater 4 5 kW 400V 3N AC 50 Hz 3 x 16...

Page 9: ...re given for 230V 1N power supply Specifications for 230V 1N connection 4 5 kW 3x 1500 W 6 0 kW 3x 2000 W 7 5 kW 3x 2500 W A1 A2 A3 B1 B2 B3 Thermostat Sicherheits temperaturbegrenzer M Zeitschaltuhr...

Page 10: ...all so that there is approx 3 mm space between the wall and the head of the screw Fig 2 2 berpr fen Sie dass die Zuleitung span nungslos ist um die Ofenzuleitung an zuschlie en First unscrew the four...

Page 11: ...and the two lock screws U V W N N PE N Z Y X L N PE 230V AC A Strahlblech U V W N N PE N Z Y X 400V 3N AC Fig 4 1 Connection line Screws 4 2 x 9 5 Corrugated head screws 2 9 x 19 Connection terminal...

Page 12: ...necessary The design of the cabin can impact on the way the cabin heats up and cause tem perature differences of up to 15 C Also many bimetal thermometers wall moun ted react sluggishly so that the re...

Page 13: ...13 EN Position change control panel left right safety screw 2 9 x 19 Fig 1 Fig 2 Fig 3 Fig 5 Fig 4 2 1 6 180 4 7 8 9 3 10 5...

Page 14: ...14 EN Replacement of heating elements Fig 1 Fig 2 Fig 4 Fig 3 1 3 2 6 7 4 5...

Page 15: ...more essences or volatile oils than advised on the packaging Never use alcohol or undiluted concentrates Cau tion Fire hazard All sauna heating units are made of low corro sion material To enjoy your...

Page 16: ...l units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air It...

Page 17: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Page 18: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Reviews: