9
T
hese amounts are reachable, although
they are higher than the amounts actually
needed.
Therefore, reduce the amounts after the
preheat cycle; to do so, set a lower value
using the program key
Ã
. Please note that
the cabin temperature is highest under the
cabin ceiling, although the relative humidity
is proportionally lower at this point. The
relative humidity rises in proportion to the
falling temperatures from the cabin ceiling
to the cabin floor.
The following diagram (Illust. 16) shows
you the temperature values proportional to
the relative humidity for the most common
types of sauna bathing and comfort zones.
In the case of the symmetrically wired oven
(equal heating power for each phase), one-
third of the heating power of the sauna oven
is consequently switched off. This serves
both to protect the user from excessive
temperatures as well as to limit the switch
capacity to 3 kW per phase.
The humidity level aimed for depends
strongly on the configuration of the sauna
cabin, the type of sauna oven used and the
power of the vaporizer. Therefore, it is
important that you find your personal climate
zone. Always choose the temperature first
(from 30 to 60°C) and then the steam level.
Tip: For the preheating time, select a higher
steam level (=duration of operation), so that
the volume of water contained in the
vaporizer (up to 8 liters depending on the
model) will be heated more rapidly. When
the oven and vaporizer are optimally
adjusted to the sauna cabin, the values for
humidity given in Illust.15 can be reached at
100% duration of operation.
Operation using the vaporizer function is
activated via the middle CLIMA key
Ä
. The
value set for the last operating cycle
appears in the display (in case of first-time
operation, this is 0). With the two
programming keys placed to the left and
right of the CLIMA key, (up and down),
Illust.13, you can program in amounts
between 0 and 99%.
Illust. 13
Press CLIMA key once
The vaporizer is always activated when an
amount between 1 and 99% is shown in
the display. When the display shows 0,
please note that the vaporizer is not
activated, but as with steam operation in
general, the maximum temperature in the
cabin is limited to 65°C. Please note also
that the vaporizer starts up only after the
temperature falls to this level.
The value shown in the display reflects the
time-proportional vaporizer adjustment.
Therefore, the display cannot be adjusted
for or show the relative humidity, but rather
the frequency of vaporizer activation. The
table (Illust.14) is meant to clarify this.
Amount shown
Vaporizer
in display
On
Off
99
99 %
1 %
75
75 %
25 %
50
50 %
50 %
25
25 %
75 %
0 0
100 %
Illust. 14
Please note: During the activation of the
vaporizer, the oven heats with only two
phases; that is, one of the switch phases
is switched to the vaporizer.
Temperature Relative humidity
60
°
C
50 %
50
°
C
60 %
40
°
C
70 %
30
°
C
80 %
Illust. 15
english