9

T

hese amounts are reachable, although

they are higher than the amounts actually
needed.

Therefore, reduce the amounts after the
preheat cycle; to do so, set a lower value
using the program key

 

Ã

.  Please note that

the cabin temperature is highest under the
cabin ceiling, although the relative humidity
is proportionally lower at this point.  The
relative humidity rises in proportion to the
falling temperatures from the cabin ceiling
to the cabin floor.

The following diagram (Illust. 16) shows
you the temperature values proportional to
the relative humidity for the most common
types of sauna bathing and comfort zones.

In the case of the  symmetrically wired oven
(equal heating power for each phase), one-
third of the heating power of the sauna oven
is consequently switched off.  This serves
both to protect the user from excessive
temperatures as well as to limit the switch
capacity to 3 kW per phase.

The humidity level aimed for depends
strongly on the configuration of the sauna
cabin, the type of sauna oven used and the
power of the vaporizer.  Therefore, it is
important that you find your personal climate
zone.  Always choose the temperature first
(from 30 to 60°C) and then the steam level.

Tip:  For the preheating time, select a higher
steam level (=duration of operation), so that
the volume of water contained in the
vaporizer (up to 8 liters depending on the
model) will be heated more rapidly.  When
the oven and vaporizer are optimally
adjusted to the sauna cabin, the values for
humidity given in Illust.15 can be reached at
100% duration of operation.

Operation using the vaporizer function is
activated via the middle CLIMA key  

Ä

.   The

value set for the last operating cycle
appears in the display (in case of first-time
operation, this is 0).  With the two
programming keys placed to the left and
right of the CLIMA key, (up and down),
Illust.13, you can program in amounts
between 0 and 99%.

Illust. 13

Press CLIMA key once

The vaporizer is always activated when an
amount between 1 and 99% is shown in
the display.  When the display shows 0,
please note that the vaporizer is not
activated, but as with steam operation in
general, the maximum temperature in the
cabin is limited to 65°C.  Please note also
that the vaporizer starts up only after the
temperature falls to this level.

The value shown in the display reflects the
time-proportional vaporizer adjustment.
Therefore, the display cannot be adjusted
for or show the relative humidity, but rather
the frequency of vaporizer activation.  The
table (Illust.14) is meant to clarify this.

Amount shown

    Vaporizer

in display

             On

        Off

99

99 %

1 %

75

75 %

25 %

50

50 %

50 %

25

25 %

75 %

 0                            0

100 %

Illust. 14

Please note:  During the activation of the
vaporizer, the oven heats with only two
phases; that is, one of the switch phases
is switched to the vaporizer.

Temperature            Relative humidity

60

°

C

50 %

50

°

C

60 %

40

°

C

70 %

30

°

C

80 %

Illust. 15

english

Summary of Contents for ECON H1

Page 1: ...1 Druck Nr 29342787en 22 06 Installation and user s manual ECON H1 IP x4 GB...

Page 2: ...le through connection to circuit breakers Heating time shut off 6 h or optionally 12 h after removal of resistance Display two digit 7 segmented display Protection type IPx4 in accordance with DIN Ger...

Page 3: ...r sauna ovens up to 9 kW Up to 36 kW when combined with a breaking capacitor l Completely disconnect the control unit from the electrical circuit i e flip all circuit breakers or the main circuit brea...

Page 4: ...luded spacer tubes as shown in Illust 3 3 3 3 Illust 3 3 Illust 3 2 Illust 3 1 15 cm ca 34 cm 20 cm ca 20 cm Illust 2 Illust 4 lead hole for oven connector lead hole for vaporizer connector lead hole...

Page 5: ...ntrol unit Warning Always connect the sauna oven s neutral conductor During steam operation one of the phases shuts down therefore the heat doesn t spread evenly In consequence the neutral conductor b...

Page 6: ...amp must be splashproof by Standard IP54 and suitable for temperatures up to 140 C The sauna lamp can be mounted anywhere except in the area of the rising hot air above the oven 2 3 Connecting the sen...

Page 7: ...now be interrupted Illust 12 LED display heating red display for humidity level LED display operational green button for decreasing value button for CLIMA mode temperature selection function selection...

Page 8: ...ight up Depending on the current temperature in the sauna cabin the sauna oven s red operational display will light up signaling the oven is heating Use the right hand dial to set the desired cabin te...

Page 9: ...r up to 8 liters depending on the model will be heated more rapidly When the oven and vaporizer are optimally adjusted to the sauna cabin the values for humidity given in Illust 15 can be reached at 1...

Page 10: ...zzer providing an acoustical signal as an additional warning when the thermostat in the vaporizer registers a water deficit 4 Troubleshooting Unit cannot be put in operation mode Check to see whether...

Page 11: ...rature An important value is the resistance at nor mal room temperature At 20 C this is about 1 9 k To determine the temperature on the temperature sensor you can measure the low voltage on the sensor...

Page 12: ...ration or handling through non authorized persons are not covered under the terms of warranty In the event of a claim please indicate the serial number as well as the article code number and type name...

Reviews: