2
Contents
1.
General information
1.1
Technical Data
1.2
Package contents
1.3
General safety precautions
2.
Assembly of the control unit
2.1
Wall mounting
2.2
Electrical connection
2.2.1 Connecting the sauna oven
2.2.2 Connecting the vaporizer
2.2.3 Connecting the sauna lamp
2.3
Connecting the sensor lines
3.
Operation
3.1.1 Dry (Finnish) sauna
3.2
Steam operation
3.2.1 Supplemental heating function
3.2.2 Low water shutoff
4.
Troubleshooting
4.1.1 Error indicator in display
4.2
Overheat safety shutoff
4.3
Monitoring the temperature sensor
5.
Heating time extension
6.
Guarantee
Manufacturer’s warrenty
1. General information
1.1
Technical data
Rated voltage:
400 V 3 N 50 Hz AC
Breaking capacity:
max 9 kW resistive load (AC 1 operation) Climatic operation: 6
kW + 3 kW for vaporizer unit, upgrade to 36 kW possible through
connection to circuit breakers
Heating time shut-off:
6 h or optionally 12 h after removal of resistance
Display:
two-digit, 7 segmented display
Protection type:
IPx4 in accordance with DIN (German Standards Institution)
40050, Splashproofing
Control range, sauna operation: 70 to 110° C
Control range, steam operation: 30 to 65° C
during steam operation control: time proportional vaporizer
control
Sensor system:
KTY-Sensor with overheat shutoff protection at 139° C
Water level control:
low water level in the vaporizer causes automatic shutoff after
two minutes of low water level
Control characteristics:
digital two-step control of -20° C - max. cab temperature
Ventilation capacity:
max. 200 W max. 1A
Light:
max 200 W max. 1A
Supplemental heating function: 20 min after shutoff of steam program
Error display:
blinking LED for connector interruption to oven sensor
connector interruption or failure of the safety temperature
shutoff
Environmental temperature: 0º C to + 40º C
Storage temperatures:
20º C to +70º C
english