21
Initial Installation
QUALIFIED INSTALLERS ONLY
h
oRizontaL
t
eRmination
- R
eaR
V
ent
with
no
V
eRticaL
R
ise
:
12” (31 cm) Max. vent length
Max. 1 x 45
˚
Elbow
Approved horizontal termination
Figure 22. Corner Rear Vent
Approved through wall thimble
The Q2 can be installed in rear vent applications with no vertical rise within the parameters as shown in
Figures 28 and 29.
Figure 23. Flat to Wall Rear Vent
6” (15 cm) Min. vent length
18” (46 cm) Max. vent length
Approved horizontal termination
Approved through wall thimble
Note: For every 12” (305mm) of
horizontal venting travel there
should be at least 1/4: (6.4mm) of
vertical travel.