Figure 19. Non-Combustible Clearances
m
antLe
& n
on
-c
ombustibLe
c
LeaRances
:
4 58 " (417mm)
Distance from a side wall
42"
(1067mm)
49"
(1245mm)
Unit can be placed on the floor
12" (305mm)
Mantle
2" (51mm)
Mantle
When installing the Q2 as a zero clearance fireplace the correct clearances and materials must be used:
a
boVe
u
nit
:
A minimum 10” of non-combustible facing material, with a R-Value no less than 0.26, must
be used above the unit (in front of the included steel framing plate).
i
n
f
Ront
of
u
nit
:
a
Djacent
/s
iDewaLL
:
There must be a minimum distance of
4 5/8” (417mm)
from the side of the Q2
cabinet to an adjacent wall composed of combustible material (see Figure 19).
m
antLe
:
It is not necessary to install a mantle, but if one is desired the guidelines as shown in Figure 19
Initial Installation
QUALIFIED INSTALLERS ONLY