25
Figure 28: Baffle plate screws
Figure 29: Baffle plate adjustment
i
nstaLLing
the
u
nit
:
• Remove the packaging from the appliance and check to make sure there is no damage. Carefully check
the glass door. Do not use the unit if it is damaged. In the event damage is found, please report it to
your dealer as soon as possible.
• Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes
or soot being blown into the room and may cause a fire leading to death or serious injury.
instaLLation instRuctions:
1. Plan your installation and clearances to combustibles. The E44 may be installed and vented into any
solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local
building codes and has been constructed of non-combustible materials. Also refer to the Also refer
C
learanCes
to
C
ombustIbles
section.
2.
Remove door. See
m
aIntenanCe
anD
s
erVICe
- g
lass
D
oor
r
emoVal
.
3. Remove wrapping material from log and embers and check for any damage. If damage is observed,
do not use unit and contact your local dealer.
4. Check that the chimney clean outs fit properly. The flue damper must be fully blocked open or removed
for installation of the E44; the smoke shelves, shields and baffles may be removed if attached by
mechanical fasteners.
2ft (0.6m)
Minimum
3ft (0.9m)
Minimum
Within
10ft (3m)
Roof ridge or
any other portion
of a building
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 30:
Roof Clearances�
5. Stretch the Ø3” (76mm) flex
vent liners to the length needed
to ensure they can be easily
connected to the vent terminals.
6. Install the flex pipe assembly
up through the chimney, ensure
that the pipe slides through far
enough to connect onto the vent
cap. Refer to table 6 to confirm
the vent cap is approved for use.