enting
:
WARNING: This appliance has been designed to draw room air for proper heat circulation from
the sides and bottom of the unit, and out the top front. Blocking or modifying these openings
in any way can create hazardous situations�
The vent length for the E44 must be between 10ft (3.05 m) and 40ft (12 m).
This model is vented with a 3” intake and a 3” exhaust aluminum or stainless steel flex vent leading into
a vertical termination cap. The flue collars of this model will fit inside of a standard 3” vent and must be
fastened directly to the vent with three screws.. The exhaust vent and air intake are both located on the top
of the unit.
Check periodically that the vents are unrestricted. Also ensure that all direct vent pipes have been properly
sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must be installed
in the correct locations on the top of the E44.
Figure 25:
Installation with a non-combustible build out�
Non-Combustible
Facing Material Onl
y
Surround Panel
Non-Combustible
Framin
g
i�e� steel stud
All Sides of Build Out
Sealed off
Finished Opening
Dimensions (H x W) =
Surround Panel - Desired Overla
p
Initial Installation